1206L050YR Littelfuse Inc, 1206L050YR Datasheet - Page 2

THERMISTOR PTC 6V .50A RESETTABL

1206L050YR

Manufacturer Part Number
1206L050YR
Description
THERMISTOR PTC 6V .50A RESETTABL
Manufacturer
Littelfuse Inc
Series
POLYFUSE® 1206Lr
Datasheets

Specifications of 1206L050YR

Package / Case
1206 (3216 Metric)
R Min/max
0.150 ~ 0.700 Ohm
Voltage - Max
6V
Time To Trip
0.1s
Current - Hold (ih) (max)
500mA
Current - Trip (it)
1A
Current - Max
100A
Hold Current
0.5 Amp
Trip Current
1 Amp
Current Rating (max)
40 Amps
Resistance
0.6 Ohms
Maximum Voltage
6 VoltsDC
Termination Style
SMD/SMT
Mounting Style
SMD/SMT
Current Rating
40 Amps
Dimensions
3.15 mm L x 1.65 mm W x 1.12 mm H
Operating Temperature Range
- 40 C to + 85 C
Holding Current
500mA
Tripping Current
1A
Initial Resistance Max
0.700ohm
Operating Voltage
6VDC
Ptc Fuse Case
1206
External Depth
0.6mm
Fuse Terminals
SMD Caps
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1206L050-C
1206L050C
1206L050WRT
F2112TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1206L050YR
Manufacturer:
LITTLEFUSE
Quantity:
55 000
Part Number:
1206L050YR
Manufacturer:
LITTEIFUSE
Quantity:
24 000
Part Number:
1206L050YR
Manufacturer:
LITTELFUSE
Quantity:
2 221
Part Number:
1206L050YR
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
1206L050YRHF
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
The average time current curves and Temperature Rerating curve performance is affected
by a number or variables, and these curves provided as guidance only. Customer must
verify the performance in their application.
1206L Series
Temperature Rerating
Average Time Current Curves
1206L075/13.2
Part Number
1206L035/16
1206L050/15
1206L075TH
1206L150TH
1206L110TH
1206L020
1206L025
1206L035
1206L050
1206L200
1206L012
1206L016
1206L175
0.01
100
0.1
10
1
0.1
Current in Amperes
-40°C
0.18
0.22
0.28
0.37
0.50
0.50
0.71
0.71
2.18
2.50
2.60
1.14
1.14
1.52
1
POLYFUSE
-20°C
0.16
0.20
0.25
0.33
0.45
0.45
0.64
0.64
2.25
2.44
1.04
1.01
1.37
1.94
Surface Mount > 1206L Series
1206L
0.14
0.18
0.23
0.29
0.40
0.40
0.57
0.57
0.88
0.88
2.00
2.35
1.25
1.72
0°C
10
®
Revised: August 20, 2010
Resettable PTCs
Ambient Operation Temperature
0.125
23°C
0.16
0.20
0.25
0.35
0.35
0.50
0.50
0.75
0.75
2.00
1.10
1.50
1.75
28
Hold Current (A)
Temperature Rerating Curve
170%
150%
130%
110%
90%
70%
50%
30%
10%
40°C
0.14
0.22
0.30
0.30
0.42
0.42
0.65
0.65
0.92
0.10
0.17
1.28
1.55
1.78
-40 -30 -20
Please refer to www.littelfuse.com/series/1206L.html for current information.
50°C
0.09
0.20
0.27
0.27
0.39
0.39
0.59
0.59
0.82
0.12
0.15
1.45
1.67
1.17
-10
0
10
Specifications are subject to change without notice.
Temperature (°C)
60°C
0.08
0.24
0.24
0.35
0.35
0.54
0.54
0.75
0.10
0.14
0.17
1.06
1.35
1.50
20
30
40
70°C
0.07
0.09
0.21
0.21
0.31
0.31
0.49
0.49
0.64
0.96
0.12
0.15
1.25
1.45
50
60
© 2010 Littelfuse, Inc.
70
85°C
0.05
0.08
0.09
0.12
0.15
0.15
0.25
0.25
0.41
0.41
0.52
0.77
1.10
1.10
80

Related parts for 1206L050YR