MAX16060ATE+T Maxim Integrated Products, MAX16060ATE+T Datasheet - Page 7

IC UP SUPERVISOR QUAD 16-TQFN

MAX16060ATE+T

Manufacturer Part Number
MAX16060ATE+T
Description
IC UP SUPERVISOR QUAD 16-TQFN
Manufacturer
Maxim Integrated Products
Type
Multi-Voltage Supervisorr
Datasheet

Specifications of MAX16060ATE+T

Number Of Voltages Monitored
4
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
140 ms/Adjustable Minimum
Voltage - Threshold
1.8V, 2.5V, 3.3V, Adj
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PIN
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
MARGIN
RESET
NAME
OUT3
OUT4
OUT2
OUT1
GND
WDI
V
SRT
TOL
IN3
IN4
MR
IN1
IN2
EP
CC
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1% Accurate, Quad-/Hex-/Octal-Voltage
Monitored Input Voltage 3. See Table 1 for the input voltage threshold.
Monitored Input Voltage 4. See Table 1 for the input voltage threshold.
Watchdog Timer Input. If WDI remains low or high for longer than the watchdog timeout period, RESET
is asserted. The timer clears whenever a reset is asserted or a rising or falling edge on WDI is detected.
The watchdog timer enters a startup period that allows 54s for the first transition to occur before a reset.
Leave WDI unconnected to disable the watchdog timer. The WDI unconnected-state detector uses a
small 400nA current. Therefore, do not connect WDI to anything that will source or sink more than
200nA. Note that the leakage current specification for most three-state drivers exceeds 200nA.
Ground
Unmonitored Power-Supply Input
O utp ut 3. When the vol tag e at IN 3 fal l s b el ow i ts thr eshol d , OU T3 g oes l ow and stays l ow unti l the vol tag e at
IN 3 exceed s i ts thr eshol d . The op en- d r ai n outp ut has a 30µA i nter nal p ul l up to V
O utp ut 4. When the vol tag e at IN 4 fal l s b el ow i ts thr eshol d , OU T4 g oes l ow and stays l ow unti l the vol tag e at
IN 4 exceed s i ts thr eshol d . The op en- d r ai n outp ut has a 30µA i nter nal p ul l up to V
Active-Low Manual Reset Input. Pull MR low to assert RESET low. RESET remains low for the reset
timeout period after MR is deasserted. MR is pulled up to V
Set Reset Timeout Input. Connect a capacitor from SRT to GND to set the reset timeout period. The reset
timeout period can be calculated as follows:
Reset Timeout (s) = 2.06 x 10
SRT to V
Active-Low Manual Deassert Input. Pull MARGIN low to deassert all outputs (go into high state),
regardless of the voltage at any monitored input.
O utp ut 2. When the vol tag e at IN 2 fal l s b el ow i ts thr eshol d , OU T2 g oes l ow and stays l ow unti l the vol tag e at
IN 2 exceed s i ts thr eshol d . The op en- d r ai n outp ut has a 30µA i nter nal p ul l up to V
O utp ut 1. When the vol tag e at IN 1 fal l s b el ow i ts thr eshol d , OU T1 g oes l ow and stays l ow unti l the vol tag e at
IN 1 exceed s i ts thr eshol d . The op en- d r ai n outp ut has a 30µA i nter nal p ul l up to V
Active-Low Reset Output. RESET asserts low when any of the monitored voltages falls below its
respective threshold or MR is asserted. RESET remains asserted for the reset timeout period after all
monitored voltages exceed their respective thresholds and MR is deasserted. This open-drain output
has a 30µA internal pullup.
Monitored Input Voltage 1. See Table 1 for the input voltage threshold.
Monitored Input Voltage 2. See Table 1 for the input voltage threshold.
Threshold Tolerance Input. Connect TOL to GND to select 5% threshold tolerance. Connect TOL to V
to select 10% threshold tolerance.
Exposed Pad. EP is internally connected to GND. Connect EP to the ground plane to provide a low
thermal resistance path from the IC junction to the PCB. Do not use as the electrical connection to GND.
CC
.
6
(Ω) x C
SRT
(F). For the internal timeout period of 140ms (min), connect
FUNCTION
Pin Description (MAX16060)
CC
through a 20kΩ resistor.
µP Supervisors
C C
C C
C C
C C
.
.
.
.
CC
7

Related parts for MAX16060ATE+T