MAX701EPA+ Maxim Integrated Products, MAX701EPA+ Datasheet - Page 4

IC PWR-SUP MONITOR W/RESET 8-DIP

MAX701EPA+

Manufacturer Part Number
MAX701EPA+
Description
IC PWR-SUP MONITOR W/RESET 8-DIP
Manufacturer
Maxim Integrated Products
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of MAX701EPA+

Number Of Voltages Monitored
1
Output
Push-Pull, Push-Pull
Reset
Active High/Active Low
Reset Timeout
200 ms Minimum
Voltage - Threshold
4.65V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Monitored Voltage
3 V to 15 V
Output Type
Active High, Active Low, Push-Pull
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Supply Voltage (max)
15 V
Supply Voltage (min)
3 V
Supply Current (typ)
200 uA
Maximum Power Dissipation
380 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Undervoltage Threshold
4.5 V
Overvoltage Threshold
4.75 V
Power-up Reset Delay (typ)
500 ms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power-Supply Monitor with Reset
4
MAX700
_______________________________________________________________________________________
1
2
3
4
5
6
7
8
MAX701
2, 3, 7
PIN
1
4
6
5
8
MAX702
4, 5, 6, 8
1
3
7
2
SENSE
RESET
RESET
NAME
HYST
GND
N.C.
CTL
V
MR
CC
Input for Manual Pushbutton Reset. Has internal 5µA pullup. Low input activates the
RESET/RESET outputs.
The voltage-sense input when CTL = V
remains connected to the internal comparator. So, when V
internally (CTL = GND), SENSE should be left open circuit.
Normally NOT used when voltage is monitored through V
monitoring through SENSE (CTL = V
reducing noise and spurious reset activity (Figure 3). HYST turns on 5µs before the
RESET/RESET outputs are activated, and its on-resistance to GND is typically 1kΩ.
Ground
Goes low when V
when SENSE falls below 1.29V.
Inverted Version of RESET
When C TL = GN D , V
and S E N S E i s m oni tor ed , al l ow i ng the thr eshol d to b e set w i th exter nal r esi stor s.
Chip Power and +5V Sensing Input (When CTL = GND on MAX700)
No Connection
CC
C C
falls below 4.65V, or when CTL = V
i s m oni tor ed b y the r eset ci r cui t. When C TL = V
CC
FUNCTION
CC
), HYST allows hysteresis to be added,
. Its threshold is 1.29V. SENSE always
CC
CC
Pin Description
CC
on the MAX700 goes low
(CTL = GND). When
is being monitored
C C
, V
C C
i s i g nor ed

Related parts for MAX701EPA+