TISP4070L3BJR Bourns Inc., TISP4070L3BJR Datasheet
TISP4070L3BJR
Specifications of TISP4070L3BJR
Available stocks
Related parts for TISP4070L3BJR
TISP4070L3BJR Summary of contents
Page 1
MODEM Protection against: - TIA/EIA-IS-968 Type A & B surge (formally FCC Part 68 60950, Clause 6. power cross - CSA 22.2 No. 60950, Clause 6. power cross Ring-Tip Protection ..........................TISP4350L3BJ Electronics Protection..........................TISP4070L3BJ Ion-Implanted Breakdown Region Precise and ...
Page 2
TISP4xxxL3BJ Overvoltage Protector Series Description (continued) For metallic protection, the TISP4350L3BJ is connected between the Ring and Tip conductors. For longitudinal protection, two TISP4350L3BJ protectors are used; one between the Ring conductor to ground and the other between the Tip ...
Page 3
TISP4xxxL3BJ Overvoltage Protector Series Electrical Characteristics for the R and T Terminals Parameter Repetitive peak off DRM D DRM state current V Breakover voltage dv/dt = ±250 V/ms, R (BO) dv/dt ≤ ...
Page 4
TISP4xxxL3BJ Overvoltage Protector Series Parameter Measurement Information V DRM -v I DRM I (BO) V (BO) Quadrant III Switching Characteristic Figure 1. Voltage-current Characteristic for T and R Terminals AUGUST 1999 - REVISED JANUARY 2007 Specifications are subject to change ...
Page 5
TISP4xxxL3BJ Overvoltage Protector Series Thermal Information 3.5 2.5 Figure 2. Peak Overload On-state Current against Duration PEAK OVERLOAD ON-STATE CURRENT vs CURRENT DURATION 40 TISP4xxxL3BJ WILL 35 30 CARRY CURRENT 25 OF TESTS 1 THRU 100 ...
Page 6
TISP4xxxL3BJ Overvoltage Protector Series FCC Part 68, ACTA, TIA and EIA From 2001, the registrations for FCC equipment changed from the FCC to ACTA, Administrative Council for Terminal Attachments. For this function, ACTA needed to adopt a US National standard ...
Page 7
TISP4xxxL3BJ Overvoltage Protector Series IEC 60950, UL 1950/60950, CSA C22.2 No. 950/60950 and EN 60950 (continued) In December 2000, UL released UL 60950, which will run concurrently with UL 1950 until 2003, after which submittals can only be made for ...
Page 8
TISP4xxxL3BJ Overvoltage Protector Series IT Equipment parameters Clause 6.4 — Protection against overvoltage from power line crosses A Connects to outside cable Yes B Has 2 100 A s ≤ @ 600 V † ) Yes Has C 1.3 A ...
Page 9
TISP4xxxL3BJ Overvoltage Protector Series Power Cross Pass Routes This discussion covers typical modem flows. Flow tests Fail APPLICATIONS INFORMATION Box A ...
Page 10
TISP4xxxL3BJ Overvoltage Protector Series Power Cross Pass Routes (continued) Flow Pass Fail Fail Pass N AUGUST ...
Page 11
TISP4xxxL3BJ Overvoltage Protector Series TISP4xxxL3BJ and UL 60950 Power Cross The TISP4xxxL3BJ conducts current for periods greater than the power cross test times, Figure 2, so the TISP4xxxL3BJ is not a major factor in UL 60950 compliance. The main design ...
Page 12
TISP4xxxL3BJ Overvoltage Protector Series Fuses for UL 60950 Fuses for the UL 1950 power cross need to break the specified currents at 600 V a.c. - ordinary fuses will not do! Fuse specification terms like short circuit capabilities to UL ...
Page 13