ETFV14K130E2 EPCOS Inc, ETFV14K130E2 Datasheet - Page 5

VARISTOR THERMAL 130VRMS 14MM

ETFV14K130E2

Manufacturer Part Number
ETFV14K130E2
Description
VARISTOR THERMAL 130VRMS 14MM
Manufacturer
EPCOS Inc
Series
ThermoFuser
Datasheet

Specifications of ETFV14K130E2

Varistor Voltage
205V
Current-surge
6kA
Number Of Circuits
1
Maximum Ac Volts
130VAC
Maximum Dc Volts
170VDC
Energy
50J
Package / Case
Disc 14mm
Product
MOV
Voltage Rating Dc
170 V
Voltage Rating Ac
130 V
Clamping Voltage
340 V
Peak Surge Current
6 KA
Surge Energy Rating
50 J
Capacitance
650 pF
Operating Temperature Range
- 40 C to + 85 C
Mounting
Through Hole
Dimensions
14 mm Dia. x 11.2 mm W x 22 mm L x 22 mm H
Lead Spacing
7.5 mm, 5 mm
Termination Style
Through Hole
Tolerance
10 %
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
495-3635
Reliability data
Test
Varistor voltage
Clamping voltage
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Abnormal overvoltage test
Please read Cautions and warnings and
Important notes at the end of this document.
Test methods/conditions
The voltage between two terminals with
the specified measuring current applied
is called V
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
CECC 42 000, test C 2.1
100 surge currents (8/20 µs), unipolar,
interval 30 s, amplitude corresponding
to derating curve for 100 impulses
at 20 µs
CECC 42 000, test C 2.1
100 surge currents (2 ms), unipolar,
interval 120 s, amplitude corresponding
to derating curve for 100 impulses
at 2 ms
UL1449, limited current abnormal over-
voltage test. Apply a high AC voltage
to ThermoFuse varistor, the amplitude
of overvoltage and current limit will be
adopted from UL1449 general instruc-
tion in section 37. The specimen will be
tested on a softwood surface covered
with a double layer of white tissue
paper. The specimen is to be loosely
draped with a double layer of cheese-
cloth. The cheesecloth shall cover
openings where flame, molten or other
particles may be expelled as a result of
the test. The test result will be visually
inspected.
ThermoFuse varistors, ETFV14 series
v
(1 mA
DC
5
@ 0.2 … 2 s).
11/07
Housed varistors
Requirement
To meet the specified value.
To meet the specified value.
|
(measured in direction
of surge current)
No visible damage
|
(measured in direction
of surge current)
No visible damage
Any of these phenomena
shall not be observed, or
this specimen will be
judged as failed part.
1. Emission of flame,
2. Charring, glowing, or
3. Ignition of the enclosure.
4. Creation of any openings
∆V/V (1 mA)
∆V/V (1 mA)
molten metal, glowing
or flaming particles
through any openings
(pre-existed or created
as a result of the test)
in the product.
flaming of the supporting
surface, tissue paper,
or cheesecloth.
in the enclosure that
result in accessibility of
live parts, when judged
in accordance with
accessibility of live parts,
UL1449 section 13.
|
|
≤10%
≤10%

Related parts for ETFV14K130E2