2891097 Phoenix Contact, 2891097 Datasheet
2891097
Specifications of 2891097
Related parts for 2891097
2891097 Summary of contents
Page 1
... Please note the different connection directions of the transmission media for five-port switches: copper cables are connected at the front, glass fiber cables at the bottom. Make sure you always use the latest documentation. It can be downloaded at www.phoenixcontact.net/download. This data sheet is valid for all products listed on the following page: © PHOENIX CONTACT - 11/2009 2 Features – Increased network performance – ...
Page 2
... Order No. FL SWITCH SFN 5TX 2891152 FL SWITCH SFN 4TX/FX 2891851 FL SWITCH SFN 4TX/FX ST 2891453 FL SWITCH SFN 8TX 2891929 FL SWITCH SFN 7TX/FX 2891097 FL SWITCH SFN 7TX/FX ST 2891110 FL SWITCH SFN 6TX/2FX 2891314 FL SWITCH SFN 6TX/2FX ST 2891411 Type Order No. FL SWITCH SFN 8GT 2891673 ...
Page 3
... Perpendicular to a standard DIN rail Snapped onto a grounded DIN rail 265 g 440 g Removable COMBICON, screw-cage connector 0.2 to 2.5 mm² / 0.2 to 2.5 mm² AWG 2.5 mm² 3.6 V within the permissible voltage range 30 500 V DC for one minute Present FL SWITCH SFN… Pcs./Pkt PHOENIX CONTACT ...
Page 4
... A for 3 ms 2.4 A for 2 ms 2.9 A for 2 ms 3.1 A for 2 ms 3.4 A for 2 ms 3.4 A for 2 ms 3.6 A for 2 ms 3.3 A for 2 ms 3.1 A for 3 ms 4.2 A for 3 ms 4.4 A for 3 ms 4.4 A for 3 ms 4.4 A for 0.22 mm PHOENIX CONTACT 2 4 ...
Page 5
... Criterion B Criterion A Criterion A Criterion B Criterion A Criterion A Class ROHS EEE 2002/95/EC, WEEE 2002/96/EC, U Class I, Division 2, Groups Temp Code T5 installed in minimum IP54 enclosure c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC U Class I, Division 2, Groups Temp Code T4 installed in minimum IP54 enclosure FL SWITCH SFN… 5 PHOENIX CONTACT ...
Page 6
... FL SWITCH SFN 5TX Ord.-No.: 2891152 LNK/ACT 100 FL SWITCH SFN 5TX Figure 1 Housing examples for 5-port switches 2732_en_A X5 X5 LNK/ACT 100 FL SWITCH SFN 4TX/ SWITCH SFN 5TX with FL SEC PAC FL SWITCH SFN… FL SWITCH SFN 4TX/FX ST Ord.-No.: 2891453 LNK/ACT PHOENIX CONTACT 6 ...
Page 7
... FL SWITCH SFN 6TX/2FX ST FL SWITCH SFN 7TX/FX ST Data Transmission Speed LEDs (10/100 Mbps Switches) 10 Mbps 100 Mbps ON/blinking ON/blinking 100 OFF ON LNK/ACT LED: ON: indicates an electrical link Flashing: indicates network traffic (at high data rates the blinking constant rate) PHOENIX CONTACT FL SWITCH SFN 7TX/FX Ord.No.2891097 ...
Page 8
... The switch is designed for SELV and PELV operation at + according to IEC 61140/EN 61140. Only SELV and PELV according to the defined standards may be used for supply purposes. Snapping the switch onto a grounded DIN rail connects it to the ground potential environment particularly prone to FL SWITCH SFN… 8 PHOENIX CONTACT ...
Page 9
... US1 GND US2 GND R1 FL SWITCH SFN…GT… power connections for redundant power supply Alarm Contact The contact closes if one or both power supplies fail. The contact opens if power is OK. Ethernet Interface can be connected. The data PHOENIX CONTACT FL SWITCH SFN… ...
Page 10
... Once attached, the security frames are permanently mounted and cannot be removed. Inserted cables or gray port blocking security caps are now locked into place. Instructions for using the key to unlock the cables or security caps are included in the kit. PHOENIX CONTACT FL SWITCH SFN… SWITCH SFN 7TX/FX Ord.No.2891097 ...
Page 11
... After prioritization the packets are forwarded without modification. 2732_en_A 8 Dimensions SWITCH SFN 5TX Ord.-No.: 2891152 X1 X2 120 LNK/ACT 100 30 mm Figure 10 Housing dimensions FL SWITCH SFN… FL SWITCH SFN 8TX Ord.-No.: 2891929 PHOENIX CONTACT ...
Page 12
... Mbps (gigabit) data rates. For 100 Mbps data rates divide the y axis numbers by 10. Application Guidelines 2000 3000 4000 5000 6000 7000 Frame size (bytes) Maximum loading Pause frame threshold Maximum bidirectional traffic loading per port (FL SWITCH SFN 8GT) PHOENIX CONTACT 8000 9000 9600 12 ...
Page 13
... This means that three times the overhead value must be used. Add all the application traffic (step 2.) with all the over head values (step 3.) and compare with the total available bandwidth. PHOENIX CONTACT FL SWITCH SFN… Typical Traffic Load (Mbps) 182 ...
Page 14
... PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 2732_en_A PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 1000 Mb switch, any additional traffic across the transmission line could result in frame loss. ...