BXRA-W0261-00000 Bridgelux, BXRA-W0261-00000 Datasheet - Page 4

LED ARRAY WARM WHITE 260LM

BXRA-W0261-00000

Manufacturer Part Number
BXRA-W0261-00000
Description
LED ARRAY WARM WHITE 260LM
Manufacturer
Bridgelux
Series
LSr
Type
Without Connectorr
Datasheet

Specifications of BXRA-W0261-00000

Color
White, Warm
Luminous Flux @ Current - Test
295 lm
Current - Test
700mA
Current - Max
1.2A
Driver Circuitry
No
Voltage
6.3V
Wavelength
3000K
Configuration
Rectangle
With Connector
No
Voltage - Input
6.3V
Led Color
Warm White
Luminous Flux @ Test
295lm
Cct
3700K
Forward Current @ Test
700mA
Forward Current If Max
1.2A
Forward Voltage @ Test
6.3V
Viewing Angle
120°
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Power - Input
-
Other names
976-1018

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BXRA-W0261-00000
Manufacturer:
Bridgelux
Quantity:
135
UL Recognition
Bridgelux product became UL Recognized on 31 March, 2010. Please refer to the UL file E333389.
Bridgelux uses UL Recognized materials with suitable flammability ratings in the LED Array to streamline
the process for customers to secure UL listing of the final luminaire product. Bridgelux recommends that
luminaires are designed with a Class 2 Driver to facilitate the UL listing process.
Minor Product Change Policy
The rigorous qualification testing on products offered by Bridgelux provides performance assurance.
Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product
optimization.
Cautionary Statements
CAUTION: CONTACT WITH OPTICAL AREA
Contact with the resin area should be avoided. Applying stress to the resin area can result in damage to
the product.
CAUTION: EYE SAFETY
Eye safety classification for the use of Bridgelux LED Arrays is in accordance with IEC specification
EN62471; Photobiological Safety of Lamps and Lamp Systems. Bridgelux LED Arrays are classified as
Risk Group 1 (Low Risk) when operated at or below their rated test current. Please use appropriate
precautions. It is important that employees working with LEDs are trained to use them safely.
CAUTION: RISK OF BURN
Do not touch the LED Array or resin area during operation. Allow the LED Array to cool for a sufficient
period of time before handling. The LED Array may reach elevated temperatures such that it can burn
skin when touched.
Bridgelux LS Array Series Product Data Sheet DS14 (03/14/11)
Page 4 of 30