E3X-NM41 Omron, E3X-NM41 Datasheet - Page 7

QUAD AUTOTUNE PNP RMT TCH

E3X-NM41

Manufacturer Part Number
E3X-NM41
Description
QUAD AUTOTUNE PNP RMT TCH
Manufacturer
Omron
Series
E3X-Nr
Type
Fiber Optic Sensorr
Datasheets

Specifications of E3X-NM41

Output Type
PNP
Amplifier Type
Four Channel
Voltage - Supply
12 V ~ 24 V
Current - Supply
150mA
Mounting Type
DIN Rail
Length/height, External
33mm
Response Time
1ms
Sensor Input
Fiber Optic
External Width
32.2mm
External Depth
59mm
Operating Temperature Min
-25°C
Operating Temperature Max
55°C
Output Current Max
100mA
Rohs Compliant
Yes
Fiber Optic Sensor Type
Fiber Optic Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNM41

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NM41
Manufacturer:
EVERLIGHT
Quantity:
20 390
E3X-N
J NO-OBJECT TEACHING
Note: 1. To detect dark objects in front of bright backgrounds, set the operation mode selector to D. ON.
J SENSITIVITY ADJUSTMENT
Combination of the E3X-NT/E3X-NM and Fine Through-beam Fiber Units (E32-T22S/T24S/T84S)
No-object Teaching
Press the teaching button once with no object in the sensing area.
Note: If detection is not stable after no-object teaching, perform
With/Without-object Teaching
Press the teaching button once with no object in the sensing area.
Procedure
1
2
3
4
5
6
2. If the set distance is very short (i.e., 0 to 12 mm for the E32-TC200 and 0 to 4 mm for the E32-DC200), no-object teaching is
3. If the teaching button is pressed for more than three seconds, the sensitivity of the E3X-Nj will be set to maximum, at which
4. The E3X-Nj will be ready to detect objects in approximately one second after the mode selector is set to RUN.
with/without-object teaching.
not possible due to excessive light, in which case, perform with/without-object teaching.
time the green indicator will be lit.
Operation
Locate the sensor head within the rated sensing range with the E3X-Nj.
Set the mode selector to TEACH.
The flashing function of the E3X-Nj will be activated. Therefore,
adjust the optical axes so that the tip of the emitting fiber will be lit. If
the optical axes are divergent, the tip of the emitting fiber will flash
and the built-in buzzer of the E3X-Nj will beep.
Press the teaching button for 0.5 to 2.5 seconds without a sensing
object. In the case the E3X-NM, select a channel with the channel
selector and press the teaching button, at which time the stability
indicator for the selected channel will flash.
The teaching indicator (red) is lit.
The built-in buzzer beeps once.
Set the mode selector to RUN. No-object teaching will be set when
the first sensing object passes through the sensing area.
The teaching indicator (red) turns green (automatically turned off in
one second).
Select the logical output required with the operation mode selector.
Object
8
E3X-NT
---
TEACH
TEACH
TEACH
RUN
RUN
L
D
ON
ON
E3X-NM
L ON
D ON
TEACH
TEACH
CH
TIMER
TIMER
RUN
RUN
SET
SET
1
TEACH
2 3 4
E3X-N

Related parts for E3X-NM41