110536-1007 ITT Cannon, 110536-1007 Datasheet - Page 11

no-image

110536-1007

Manufacturer Part Number
110536-1007
Description
RCPT HOUSING 156POS ZIF SQ POST
Manufacturer
ITT Cannon
Series
DL1r
Datasheet

Specifications of 110536-1007

Connector Type
Receptacle, Female Sockets
Connector Style
Drawer
Number Of Positions
156
Number Of Positions Loaded
All
Pitch
0.100" (2.54mm)
Number Of Rows
6
Termination
Solder
Features
Actuating Camshaft Socket
Contact Finish
Gold
Contact Finish Thickness
50µin (1.27µm)
Color
Black
Material Flammability Rating
UL94 V-1
Operating Temperature
-55°C ~ 105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Mounting Type
-
Connector Usage
-
Number Of Columns
-
Contact Layout, Typical
-
Other names
1003-1094
DL1-156RW6B
10
ZIF Connectors
DL/DLM/DLD Temperature/Current Rating
The ambient temperature curves shown represent
the rated current carrying capacity of the Cannon
DL1/2/3/4, DLM1/2/3 and DLD1/2 electrical
connectors, derated to 80% of the values recorded
using the methods specified by International
Electro-Technical Commission Document 48
(1975).
Current was applied to the total connector (all
contacts) in one-half ampere increments and
maintained at each current level until thermal
stability was achieved. A thermocouple inserted
into the ‘‘hottest area’’ of each connector then
measured the connector temperature at the same
time that an ambient temperature reading was
taken. The difference between the two measured
values is the heat rise or self-heating created solely
by the current flow, and this temperature rise for
the current level was deducted from the insulator
material rated temperature. These values were
then derated to 80% to obtain the curves shown.
DL/DLM/DLD Test Data
Test Description
Dielectric Withstanding Voltage
Contact Resistance
Insulation Resistance
Humidity (Standard)
Humidity (DL4)
Salt Spray
Shock
Vibration (Standard)
Vibration (DL4)
MIL Standard
MIL-STD-202
MIL-STD-202
MIL-STD-202
MIL-STD-202
MIL-STD-202
MIL-STD-202
MIL-STD-202
MIL-STD-202
MIL-STD 167-1/2 Modified
DL1/DLM1/DLD1
DL3/DLM3
Test Method
301
307
302, Condition B
103, Condition B
106
101, Condition B (48 Hours)
213, Condition A (50 G’s)
204, Condition C
DL2/DLM2/DLD2
DL4
DL/DLM/DLD
Dimensions are shown in mm (inch)
Dimensions subject to change

Related parts for 110536-1007