GLC65-12 SL Power Electronics Manufacture of Condor/Ault Brands, GLC65-12 Datasheet - Page 2

no-image

GLC65-12

Manufacturer Part Number
GLC65-12
Description
PWR SPLY SWITCHER 65W 12V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLC65r
Datasheet

Specifications of GLC65-12

Rohs Status
RoHS non-compliant
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
65W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 5.5A
Size / Dimension
5" L x 3" W x 1.06" H (127mm x 76.2mm x 26.9mm)
Operating Temperature
0°C ~ 50°C
Power (watts) - Rated
65W
Efficiency
94%
Approvals
CE, CSA, EN, IEC, TUV, UL
Line Regulation
2%
Load Regulation
2%
3rd Output
-
2nd Output
-
4th Output
-
Other names
271-2166
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 01/07.
Data Sheet © 2007 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS
* 9 A convection, 11 A with fan cooling
Commercial
Model
GLC65-5
GLC65-12
GLC65-15
GLC65-18
GLC65-20
GLC65-24
GLC65-28
GLC65-48
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Note:
Medical
Model
GLM65-5
GLM65-12
GLM65-15
GLM65-18
GLM65-20
GLM65-24
GLM65-28
GLM65-48
OPERATING
0 to 50°
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
rms’
Output
0.003 g
5.1 V
12 V
15 V
18 V
24 V
28 V
48 V
20V
2
/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
9/11 A *
Current
3.25 A
1.35 A
0.026 g
5.5 A
4.3 A
3.6 A
2.7 A
2.3 A
2
/Hz
Regulation
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
output power by 2.5% per °C above 50°C.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1hr./
axis non-operating.
Total
2%
2%
2%
2%
2%
2%
2%
2%
V1 Adjustment
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
1.20
30.28
V1 OVP Setpoint
18.5 ± 1.5 V
21.7 ± 2.0 V
24.5 ± 2.2 V
6.2 ± 0.6 V
14 ± 1.1 V
28 ± 2.5 V
34 ± 2.8 V
55 ± 4.0 V
and Noise
Ripple
1%
1%
1%
1%
1%
1%
1%
1%

Related parts for GLC65-12