XIB-E Digi International/Maxstream, XIB-E Datasheet - Page 15

no-image

XIB-E

Manufacturer Part Number
XIB-E
Description
BOARD INTERFACE ETHERNET
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XIB-E

Accessory Type
Interface Board
For Use With/related Products
XStream and Xcite Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up
initializer contains initialization information and all receiving modules must wake during the
wake-up initializer portion of data transmission in order to be synchronized with the transmitting
module and receive the data.
Figure 2‐08. Correct Configuration (LH > SM) 
Length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect 
the wake‐up initializer and receive the accompanying payload data. 
Figure 2‐09. Incorrect Configuration (LH < SM) 
Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable 
to the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data). 
 
   © 2006 MaxStream, Inc. Confidential and Proprietary 
15 