FCTN-WALL-315 Linx Technologies Inc, FCTN-WALL-315 Datasheet

MODULE AC SWITCH RECEIVER 315MHZ

FCTN-WALL-315

Manufacturer Part Number
FCTN-WALL-315
Description
MODULE AC SWITCH RECEIVER 315MHZ
Manufacturer
Linx Technologies Inc
Datasheet

Specifications of FCTN-WALL-315

Function
Receiver, Relay
Modulation Or Protocol
ASK, OOK
Frequency
315MHz
Applications
General Remote Control, Wire Elimination
Interface
Receiver, Latched Output
Sensitivity
-95dBm
Data Rate - Maximum
1.2 kbps
Features
Switch 1,800W (15 Amps) or 1HP @ 120 VAC
Voltage - Supply
100 V ~ 120 VAC
Package / Case
Module
Board Size
104.1 mm x 56.6 mm x 64.3 mm
Minimum Operating Temperature
- 30 C
Product
RF Modules
Maximum Frequency
315 MHz
Supply Voltage (max)
110 V
Supply Current
15 A
Maximum Operating Temperature
+ 70 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power - Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
FCTN-WALL-315-1
FCTN-WALL-315-1
DESCRIPTION
The AC Function Module is a member of
the Linx pre-certified OEM product line. The
module plugs directly into a wall receptacle
and is capable of switching devices at loads
of up to 1,800 watts (15 amps) or 1HP at up
to 120VAC. Devices under control connect
via a standard NEMA 5-15 North American
power plug. The AC Function module is UL
listed and has been tested for FCC and
Industry Canada compliance. Front and
rear graphics can be quickly customized for
a truely unique product appearance. This
greatly reduces the time and expense of
bringing a wireless product to market. The
AC Function Module is durably constructed
using high quality components. When
paired with a compatible Holtek-based Linx
Handheld transmitter or a Linx transmitter
module, the AC Function Module provides
reliable wireless switching over distances
of up to 500 feet.
FEATURES
n Heavy duty construction
n Switch 1,800 watts at 15 amps
n UL Listed
n FCC pre-tested
n 16 unique addresses
n Selectable group capabilities
n Standard NEMA 5-15 power plug
n Easy cosmetic customization
n Ideal for OEM applications
APPLICATIONS INCLUDE
n General Remote Control
n Process Control
n Lighting Control
n Home / Industrial Automation
n Wire Elimination
WIRELESS MADE SIMPLE
AC FUNCTION MODULE DATA GUIDE
®
PART #
FCTN-WALL-315
FCTN-WALL-418
FCTN-WALL-433
ORDERING INFORMATION
OEM Configurations
With a one-time NRE and minimum
order, Linx can configure the label areas
to meet your specific requirements.
Contact Linx for details.
Figure 1: Package Dimensions
Front
2.23"
DESCRIPTION
AC Function Module - 315MHz
AC Function Module - 418MHz
AC Function Module - 433MHz
0.9"
110-120V~ 60Hz 1800 Watts Max.
15 A Tungsten or Resistive Load
5 A Electronic Ballast
Indoor use only
1 HP (15 FLA Max.)
CAUTION
4.1"
Appliance Control
SIDE VIEW
SIDE VIEW
E334278
3TM8
2.53"
Revised 4/7/2011
4.1"
0.95"

Related parts for FCTN-WALL-315

FCTN-WALL-315 Summary of contents

Page 1

... Standard NEMA 5-15 power plug to meet your specific requirements. n Easy cosmetic customization Contact Linx for details. n Ideal for OEM applications ORDERING INFORMATION APPLICATIONS INCLUDE PART # n General Remote Control FCTN-WALL-315 n Process Control FCTN-WALL-418 n Lighting Control FCTN-WALL-433 n Home / Industrial Automation n Wire Elimination SIDE VIEW SIDE VIEW 4.1" ...

Page 2

... Tungsten or Resistive load – Electronic Ballast – Power – Power – Power – Relay Cycle Life – RECEIVER SECTION Receive Frequency Range FCTN-WALL-315 – FCTN-WALL-418 – FCTN-WALL-433 – Center Frequency Accuracy – -50 Receiver Sensitivity – -106 Noise Bandwidth N – 3dB ENVIRONMENTAL Operating Temperature Range – ...

Page 3

... In most cases, orienting the antenna in a vertical position will result in optimum performance. Wall Mount Power Strip Figure 5: FCTN-WALL-*** Antenna Orientation CONTENTION CONSIDERATIONS When working in a wireless environment it is always important to distinguish between uniqueness and contention. The address lines provided on OEM modules allow for the uniqueness of system components, however, this does not eliminate contention between transmitted signals in free space ...

Page 4

... Place the above statement in the instruction manual or insert card. LABELING REQUIREMENTS In cases where the FCTN-WALL-*** module is incorporated inside a product and its standard labeling is not visible, the end product must be labeled as shown. • ...

Page 5

TRANSMITTER ADDRESS SETTINGS The AC Function Module and the corresponding transmitter must have the same address setting in order to function together. The following figures show how to set the address on the Linx transmitters described in the previous section. ...

Page 6

... VCCA + ~ 2 3 GND - ~ Figure 12: FCTN-WALL-*** Schematic Diagram Page Replacement Fuse Values • Littelfuse p/n 326025, 25A, 125V, slow blow • Schurter p/n 7043.8230, 20A, 250V, time lag • Cooper Bussman p/n MDA-20-R, 20A, 250VAC, time delay • Littelfuse p/n 314025, 25A, 250 V, Fast Acting ...

Page 7

WIRELESS MADE SIMPLE U.S. CORPORATE HEADQUARTERS LINX TECHNOLOGIES 159 ORT LANE MERLIN, OR 97532 PHONE: (541) 471-6256 FAX: (541) 471-6251 www.linxtechnologies.com Disclaimer Linx Technologies is continually striving to improve the quality and function of its products. For this reason, ...