RXM-900-HP-II Linx Technologies Inc, RXM-900-HP-II Datasheet - Page 2

no-image

RXM-900-HP-II

Manufacturer Part Number
RXM-900-HP-II
Description
RECEIVER RF 900MHZ 8-CH PACK
Manufacturer
Linx Technologies Inc
Datasheet

Specifications of RXM-900-HP-II

Frequency
902MHz ~ 928MHz
Sensitivity
-95dBm
Data Rate - Maximum
50 kbps
Modulation Or Protocol
FM, FSK
Applications
Home / Industrial Automation, Remote Access, Security Alarms
Current - Receiving
18mA
Data Interface
PCB, Through Hole
Antenna Connector
Through Hole
Voltage - Supply
2.7 V ~ 16 V
Operating Temperature
0°C ~ 70°C
Package / Case
18-SIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Memory Size
-
Other names
RXM-900-HP2
RXM-900-HP2
Notes:
1.
2.
3.
4.
SPECIFICATIONS
Figure 2: Specifications table
Parameter
Input Voltage
Supply Current
Sleep Current
Data output:
RF input impedance
Receive frequency
Noise Bandwidth
Data Bandwidth
Audio Bandwidth
Sensitivity
DC Modulation Sensitivity
RSSI:
Spurious Emmissions
Interference Rejection:
ABOUT THESE MEASUREMENTS
Voltage/No Carrier
Logic low
Logic high
Dynamic Range
Gain
Half F
F
Over full operating voltage
Depends on CS0 - CS2 voltage levels
For 10
Minimum input power level to ensure that data output can hold a DC level
The performance parameters listed below are based on module operation at
25°C from a 5VDC supply unless otherwise noted. It is recommended all ground
pins be connected to the ground-plane. The pin marked N/C has no physical
connection and is designed only to add support.
C
±1MHz
Figure 3: Maximum ratings table
-5
C
*NOTE*
damage to the device. Furthermore, extended operation at these maximum
ratings may reduce the life of this device.
BER @ 9600 bps
Spurious
Absolute Maximum Ratings:
Supply voltage Vcc
Operating temperature
Storage temperature
Soldering temperature
RF input, pin 1
Exceeding any of the limits of this section may lead to permanent
Designation
G
N
V
V
V
I
R
I
F
SLP
DOH
3DB
RSSI
CC
DOL
CC
IN
C
903.37
V
GND
Min.
300
CC
-92
-88
2.7
16
50
60
-.3
-45°C
-0.3
0°C
Typical
+260°C for 15 sec.
280
-95
18
50
70
24
60
20
0 dBm
to
to
to
921.37
50,000
25,000
Max.
16.0
-100
V
0.5
1.6
-45
20
50
80
CC
+70°C
+85°C
18 VDC
mV/dB
Ohms
Units
Volts
VDC
VDC
MHz
dBm
dBm
dBm
KHz
Bps
mA
mV
µA
Hz
dB
dB
dB
Notes
1
2
3
4

Related parts for RXM-900-HP-II