Specifications of XBP24-ACI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
20dBm (100mW)
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
3. Associate to Valid Coordinator
4. End Device Changes once an End Device has associated
© 2009 Digi Internatonal, Inc.
The End Device selects a Coordinator to associate with according to the A1 parameter
“Reassign_PANID” and “Reassign_Channel” flags:
Reassign_PANID Bit Set (bit 0 = 1)- End Device can associate with a PAN with any ID value.
Reassign_PANID Bit Not Set (bit 0 = 0) - End Device will only associate with a PAN whose
ID setting matches the ID setting of the End Device.
Reassign_Channel Bit Set (bit 1 = 1) - End Device can associate with a PAN with any CH
value.
Reassign_Channel Bit Not Set (bit 1 = 0)- End Device will only associate with a PAN whose
CH setting matches the CH setting of the End Device.
After applying these filters to the discovered Coordinators, if multiple candidate PANs exist, the
End Device will select the PAN whose transmission link quality is the strongest. If no valid Coor-
dinator is found, the End Device will either go to sleep (as dictated by its SM (Sleep Mode)
parameter) or retry Association.
Note - An End Device will also disqualify Coordinators if they are not allowing association (A2 -
AllowAssociation bit); or, if the Coordinator is not using the same NonBeacon scheme as the
End Device. (They must both be programmed with NonBeacon code.)
Once a valid Coordinator is found (step 2), the End Device sends an AssociationRequest mes-
sage to the Coordinator. It then waits for an AssociationConfirmation to be sent from the Coor-
dinator. Once the Confirmation is received, the End Device is Associated and the Associate LED
will blink rapidly (2 times per second). The LED is solid if the End Device has not associated.
Changing A1, ID or CH parameters will cause the End Device to disassociate and restart the
Association procedure.
If the End Device fails to associate, the AI command can give some indication of the failure.