XB24-BWIT-004 Digi International/Maxstream, XB24-BWIT-004 Datasheet - Page 68

no-image

XB24-BWIT-004

Manufacturer Part Number
XB24-BWIT-004
Description
MODULE 802.15.4 SER 2 WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XBee™r
Datasheet

Specifications of XB24-BWIT-004

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
2 mW (3 dBm)
Sensitivity
-96dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
38mA
Current - Transmitting
35mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
XBee ZNet 2.5/XBee‐PRO ZNet 2.5 ZigBee OEM RF Modules v1.x4x 
**
*
N/A
CTS/DI
O7
Supply
Voltage
MSB (most significant byte) first,
LSB (least significant) last
64-bit Address
(Bytes 5-12)
MSB (most significant byte) first,
LSB (least significant) last
N/A
RTS/DI
O6
N/A
16-bit Network Address
(Bytes 13-14)
ZigBee IO Data Sample Rx Indicator
N/A
ASSOC/
DIO5
N/A
API Identifier Value: 0x92
When the module receives an IO sample frame from a remote device, it sends the sample out the
UART using this frame type.
Figure 6‐18. IO Data Sample Rx Indicators
© 2008 Digi International, Inc.
0x01 - Packet Acknowledged
0x02 - Packet was a
broadcast packet
CD/DIO
12
DIO4
N/A
Receive Options
Start Delimiter
Num Samples (byte 16)
(Byte 15)
0x7E
Number of sample sets
included in the payload.
(Always set to 1)
PWM/DI
O11
AD3/DI
O3
AD3
MSB
Length
LSB
API Identifier
RSSI/DI
O10
AD2/DI
O2
AD2
0x92
API-specific Structure
Bitmask field that indicates
which digital IO lines on the
remote have sampling
enabled (if any)
Digital Channel Mask
(bytes 17-18)*
Frame Data
Analog Channel Mask
N/A
AD1/DI
O1
AD1
Identifier-specific Data
Bitmask field that indicates
which digital IO lines on the
remote have sampling
enabled (if any).
(byte 19)**
cmdData
N/A
AD0/DI
O0
AD0
Checksum
1 Byte
If the sample set includes any digital IO lines
(Digital Channel Mask > 0), these two bytes
contain samples for all enabled digital inputs.
DIO lines that do not have sampling enabled
return 0. Bits in these 2 bytes map the same as
they do in the Digital Channels Mask field.
Digital Samples (bytes 20-
21, if included)
If the sample set includes any analog input lines
(Analog Channel Mask > 0), each enabled analog input
returns a 2-byte value indicating the A/D measurement
of that input. Analog samples are ordered sequentially
from AD0/DIO0 to AD3/DIO3, to the supply voltage.
Analog Samples (2 bytes
each sample)
     67