X24-009WNC Digi International/Maxstream, X24-009WNC Datasheet - Page 53
X24-009WNC
Manufacturer Part Number
X24-009WNC
Description
MOD RF 2.4GHZ 9600BPS W/WIRE ANT
Manufacturer
Digi International/Maxstream
Specifications of X24-009WNC
Frequency
2.4GHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
17dBm
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
80mA
Current - Transmitting
150mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Applications
-
Memory Size
-
Figure B‐01. Front View
Figure B‐02. Back View
Figure B‐03. MaxStream XIB
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24]
B‐01a.
Power
Switch
B‐01b.
LEDs
B‐02a.
DIP Switch
B‐01c.
Serial Port
B‐02b.
Config
MaxStream RS-232/485 Interface Board
‐R (RS‐232/485) Interface Board DIP Switch Settings
© 2006 MaxStream, Inc. Confidential and Proprietary
Switch
B‐0d.
Po
Connector
wer
B-01a. Power Switch
B-01b. LEDs
B-01c. Serial Port
B-01d. Power Connector
B-02a. DIP Switch
B-02b. Config (Configuration) Switch
Move the Power Switch to the on (up) position to power the
Interface Board. DIP Switch [B.2a] settings are only read
during a power-up sequence.
The LED indicators visualize diagnostic status information. The
module’s status is represented as follows:
Standard female DB-9 (RS-232) DCE connector – T
can be also used for RS-485 and RS
7-18 VDC Power Connector (Center positive, 5.5/2.1mm) – Power
can also be supplied through Pin 9 of the D
The DIP Switch automatically configures the XStrea
Module to operate in different modes. Each tim
assembly (interface board + the RF Module) is p
intelligence on the XIB-R interface board progra
according to the positions of the DIP Switch. [Se figure below
for DIP Switch settings]
NOTE: In cases where AT Commands should n
the module assembly is powered-on, the processor must be
disabled by populating J7 on the interface board.
The Configuration Switch provides an alternate way to enter “AT
Command Mode”. To enter “AT Command Mode” at the module’s
default baud rate, hold the Configuration Switch down while
powering on the module using the Power Switch [B-01a].
Yellow (top LED) = S
Green (middle) = Serial Data In (from host)
Red (botto
powered, off b
m) = Power/TX Indicator (Red light is on when
riefly during RF transmission)
erial Data Out (to host)
-422 connectio
Refer to table in the
Automatic DIP Switch
Configurations section [next
page] for more information
regarding configurations
triggered by the DIP Switch.