SI4430-B1-FM Silicon Laboratories Inc, SI4430-B1-FM Datasheet - Page 49

IC TXRX 900-960MHZ -8-13DB 20QFN

SI4430-B1-FM

Manufacturer Part Number
SI4430-B1-FM
Description
IC TXRX 900-960MHZ -8-13DB 20QFN
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI4430-B1-FM

Package / Case
20-VQFN
Mfg Application Notes
Transitioning SI4430/31 to Rev B
Frequency
900MHz ~ 960MHz
Data Rate - Maximum
256kbps
Modulation Or Protocol
ISM
Applications
General Purpose
Power - Output
13dBm
Sensitivity
-121dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
18.5mA
Current - Transmitting
30mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Wireless Frequency
900 MHz to 960 MHz
Output Power
13 dBm
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
30 mA
Minimum Operating Temperature
- 40 C
Modulation
FSK, GFSK, OOK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI4430-B1-FM
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
SI4430-B1-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si4430/31/32-B1
7. RX Modem Configuration
A Microsoft Excel parameter calculator or Wireless Development Suite (WDS) calculator is provided to determine
the proper settings for the modem. The calculator can be found on www.silabs.com or on the CD provided with the
demo kits. An application note is available to describe how to use the calculator and to provide advanced
descriptions of the modem settings and calculations.
7.1. Modem Settings for FSK and GFSK
The modem performs channel selection and demodulation in the digital domain. The channel filter bandwidth is
configurable from 2.6 to 620 kHz. The receiver data-rate, modulation index, and bandwidth are set via registers
1C–25h. The modulation index is equal to 2 times the peak deviation divided by the data rate (Rb).
When Manchester coding is disabled, the required channel filter bandwidth is calculated as BW = 2Fd + Rb where
Fd is the frequency deviation and Rb is the data rate.