ZB2430-Q-C-S-A Laird Technologies, ZB2430-Q-C-S-A Datasheet - Page 27

no-image

ZB2430-Q-C-S-A

Manufacturer Part Number
ZB2430-Q-C-S-A
Description
MOD ANT CHIP ZIGBEE 2-100MW SMT
Manufacturer
Laird Technologies
Series
AeroCommr
Datasheet

Specifications of ZB2430-Q-C-S-A

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee
Applications
AMR, ISM, Security and Access
Power - Output
10dBm ~ 20dBm
Sensitivity
-99dBm
Voltage - Supply
3 V ~ 3.5 V
Current - Receiving
27mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
2 2
S E R I A L I N T E R F A C E
I N T E R F A C E T I M E O U T / R F P A C K E T S I Z E
Interface Timeout – Interface Timeout specifies a maximum byte gap between consecutive bytes. When that byte gap
is exceeded, the bytes in the transmit buffer are processed as a complete packet. Interface Timeout (EEPROM
address 0x58), in conjunction with the RF Packet Size, determines when a buffer of data will be sent out over the RF
as a complete RF packet, based on whichever condition occurs first.
RF Packet Size - RF Packet Size is used in conjunction with Interface Timeout to determine when to delineate
incoming data as an entire packet based on whichever condition is met first. When the transceiver receives the
number of bytes specified by RF Packet Size (EEPROM address 0x5A) without experiencing a byte gap equal to
Interface Timeout, that block of data is processed as a complete packet. Every packet the transceiver sends over the
RF contains extra header bytes not counted in the RF Packet Size. Therefore, it is much more efficient to send a few
large packets than to send many short packets.
Stop Bit Delay - For systems using the RS-485 interface, the RS-485 DE pin might be deasserted Low too quickly at
the end of a packet (especially at slower interface baud rates). Stop Bit Delay (EEPROM address 0x3F) controls how
long RS-485 DE should be left High at the end of a packet before dropping it Low and disabling the RS-485 driver
circuitry. Generally, it should be set greater than or equal to two byte times.
F L O W C O N T R O L
Although flow control is not required for transceiver operation, it is recommended to achieve optimum system
performance and to avoid overrunning the ZB2430’s serial buffers. The ZB2430 uses seperate buffers for incoming
and outgoing data.
E N G I N E E R ’ S T I P
Using a non-standard baud rate.
The ZB2430 supports a majority of standard as well as non-standard baud rates. To select a
standard baud rate, use the value shown for EEPROM address 0x42 in Table 5 above. To
enable a non-standard baud rate, program EEPROM address 0x42 (Custom Baud Enable) to
0xE3 and then use the equation above to solve for BAUD_M and BAUD_E.
Stop Bit Delay
=
---------------------------------------------- -
(
Baud Rate
20
×
1ms
)

Related parts for ZB2430-Q-C-S-A