SRI512-SBN18/1GE STMicroelectronics, SRI512-SBN18/1GE Datasheet - Page 29

no-image

SRI512-SBN18/1GE

Manufacturer Part Number
SRI512-SBN18/1GE
Description
IC MEM 13.56MHZ 512BIT EEPROM
Manufacturer
STMicroelectronics
Series
SRI512r
Datasheet

Specifications of SRI512-SBN18/1GE

Rf Type
Read / Write
Frequency
13.56MHz
Features
ISO14443-B
Package / Case
Wafer
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SRI512-SBN18/1GE
Manufacturer:
ST
0
SRI512
8.1
Initiate() command
Command code = 06h - 00h
Initiate() is used to initiate the anticollision sequence of the SRI512. On receiving the
Initiate() command, all SRI512 devices in Ready state switch to Inventory state, set a new 8-
bit Chip_ID random value, and return their Chip_ID value. This command is useful when
only one SRI512 in Ready state is present in the reader field range. It speeds up the
Chip_ID search process. The Chip_slot_number is not used during Initiate() command
access.
Figure 23. Initiate request format
Request parameter:
Figure 24. Initiate response format
Response parameter:
Figure 25. Initiate frame exchange between reader and SRI512
Reader
SRI512
No parameter
Chip_ID of the SRI512
SOF
SOF
SOF
06h
06h
00h
Initiate
Chip_ID
8 bits
CRC L
Doc ID 13263 Rev 5
00h
CRC H EOF
8 bits
CRC L
<-t 0 -> <-t 1 ->
8 bits
CRC L
SOF Chip_ID
CRC H
8 bits
CRC H
8 bits
SRI512 commands
CRC L CRC H EOF
EOF
EOF
AI07671
AI07670b
AI10942
29/47