Page 1
... Applications: □ AC Motor Control □ UPS □ Battery Powered Supplies Ordering Information: Example: Select the complete part module number you desire from the table below -i.e. CM100DY-24NF is a 1200V (V ), 100 Ampere Dual CES IGBTMOD™ Power Module. Type Current Rating V CES ...
Page 2
... GE C res t d(on 600V 100A 15V, R d(off) GE1 GE2 t Inductive Load f t Switching Operation 100A does not exceed T j Symbol CM100DY-24NF T –40 to 150 j T –40 to 125 stg V 1200 CES V 20 GES I 100 C I 200 100 E I 200 650 C — 30 — 40 — ...
Page 3
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM100DY-24NF Dual IGBTMOD™ NF-Series Module 100 Amperes/1200 Volts Thermal and Mechanical Characteristics, T Characteristics Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Contact Thermal Resistance External Gate Resistance ...
Page 4
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM100DY-24NF Dual IGBTMOD™ NF-Series Module 100 Amperes/1200 Volts REVERSE RECOVERY CHARACTERISTICS (TYPICAL 600V ±15V 3 25°C j Inductive Load EMITTER CURRENT (AMPERES) E SWITCHING LOSS VS. GATE RESISTANCE (TYPICAL 600V ±15V 100A 125°C ...