Specifications of EE-SY190

Sensing Distance
0.178" (4.5mm)
Sensing Method
Reflective
Voltage - Collector Emitter Breakdown (max)
30V
Current - Collector (ic) (max)
20mA
Current - Dc Forward (if)
50mA
Output Type
Phototransistor
Response Time
30µs, 30µs
Mounting Type
Through Hole
Package / Case
PCB Mount
Operating Temperature
-25°C ~ 85°C
Termination Style
PCB
No. Of Pins
4
Opto Case Style
Through Hole
No. Of Channels
1
Operating Temperature Range
-25°C To +85°C
Peak Reflow Compatible (260 C)
No
Input Current Max
30mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Other names
EESY190
EESY190NC
OR564
Precautions
Using the photomicrosensor beyond its absolute maximum
ratings can result in diminished life expectancy, reliability, or
failure. OMRON does not assume responsibility for any change
in the characteristics and/or performance of the device due to
use beyond the absolute maximum ratings.
Electrical surges, incorrect wiring or voltage could result in
damage to the photomicrosensor.
Photomicrosensors with non-modulated light sources are not
protected against incandescent lights or sunlight and should not
be located in areas where such external light sources exists.
Photomicrosensors equipped with an internal modulated light
source are not affected by external light sources.
When installing the photomicrosensor, always mount it on a flat
surface. If mounted on a curved or irregular surface, the electrical
characteristics of the sensor can be altered due to a change in
the sensor’s orientation.
EE-SY190/191
Cat. No. EO5DAX4
1-800-55-OMRON
OMRON ELECTRONICS, INC.
One East Commerce Drive
Schaumburg, IL 60173
RATINGS
SURGE
INSTALLATION
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1/99
Specifications subject to change without notice.
For proper connection of the photomicrosensor, refer to the
terminal diagram on the data sheet. Incorrect wiring or
connections can result in damage to the photomicrosensor.
For maximum reliability and life expectancy, use the
photomicrosensor at temperatures within the rated operating
temperature range. If the ambient temperature abruptly changes
from a low (0°C or lower) to a high temperature, condensation
may occur on the surface of the light source and/or receiver, thus
causing a malfunction.
Mount the photomicrosensor in a dust-free environment. Check
that the light-receiving window is clean. If necessary, clean off the
window using a dry cloth.
Keep the photomicrosensor in a dry storage location to prevent
the terminals from corroding.
The sensing window and case of most photomicrosensor models
are made of a polycarbonate resin which withstands alcohol and
chloride solvents, but is soluble in strong alkali, aromatic
hydrocarbons, and aliphatic hydrocarbonate chloride solvents.
RELIABILITY
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
EE-SY190/191
Printed in U.S.A.