ASDX100A24R Honeywell Sensing and Control, ASDX100A24R Datasheet - Page 2

SENSOR AMP 100PSI ABS .5-4.5 OUT

ASDX100A24R

Manufacturer Part Number
ASDX100A24R
Description
SENSOR AMP 100PSI ABS .5-4.5 OUT
Manufacturer
Honeywell Sensing and Control
Series
ASDXr

Specifications of ASDX100A24R

Pressure Type
Absolute
Operating Pressure
100 PSI
Port Size
Male, 0.09" (2.28mm) Tube, Dual
Output
0 ~ 4V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Top Port
Interface Type
PCB Mount
Operating Pressure Range
0 To 100psi
Sensor Output
Voltage
Supply Current
6mA
External Depth
16.89mm
Voltage Rating
5.25V
Port Style
Straight
Pressure Measurement Type
Absolute
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287-1917
287-1917
480-1917
ASDX Series
TABLE 1. GENERAL SPECIFICATIONS
Note:
1. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply
TABLE 2. PRESSURE RANGE SPECIFICATIONS
Note:
1. If the maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
TABLE 3. PERFORMANCE SPECIFICATIONS
Notes:
1. Reference conditions (unless otherwise noted): Supply voltage, V
2. Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure. Span is ratiometric to the supply voltage.
3. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on
4. Response time for a 0 psi to full-scale pressure step change, 10% to 90% rise time.
5. The smallest change in the output voltage, given any change in pressure.
FIGURE 1. BLOCK DIAGRAM
Note:
1. 220 nF capacitor is required between +Vs and GND. 15 nF capacitor between Vout and ground is optional.
2
Supply voltage (Vs)
Maximum supply voltage
Consumption current
Output current (sink)
Output current (source)
Lead temperature
Compensated temp. range
Operating temp. range
Storage temp. range
Vibration
Shock
Life
Catalog Listing
ASDX001
ASDX005
ASDX015
ASDX030
ASDX100
Characteristic
Zero pressure offset
Full scale span
Output at FS pressure
Accuracy
Response time
Quantization step
voltage above the maximum can cause electrical failure.
a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration
errors include the deviation of offset and full scale from nominal values.
www.honeywell.com/sensing
(1)
(1)
Symbol
Vfss
Vfso
Voff
Pressure Range
0 psi to 100 psi
0 psi to 15 psi
0 psi to 30 psi
0 psi to 1 psi
0 psi to 5 psi
(1)
4.75 Vdc to 5.25 Vdc
6.50 Vdc (max.)
6 mA (typ.)
2 mA (max.)
2 mA (max.)
2 s to 4 s at 250 °C [482 °F]
0 °C to 85 °C [32 °F to 185 °F]
-20 °C to 105 °C [-4 °F to 221 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
10 g at 20 Hz to 2000 Hz
100 g for 11 ms
1 million cycles minimum
S
0.420
4.420
=5.0 ±0.01 Vdc; T
Min.
A
=25 °C [77 °F]. Output is ratiometric within the supply voltage range (Vs).
0.500
4.500
Typ.
4.00
8
3
Burst Pressure
150 psi
20 psi
30 psi
60 psi
5 psi
0.580
4.580
Max.
±2.0
(1)
Unit
Vdc
Vdc
Vdc
%V
mV
ms
Sensitivity
0.267 V/psi
0.133 V/psi
0.040 V/psi
4.00 V/psi
0.80 V/psi
Note
2
3
4
5

Related parts for ASDX100A24R