ASDX015G24R Honeywell Sensing and Control, ASDX015G24R Datasheet

SENSOR AMP 15PSI GAUG .5-4.5 OUT

ASDX015G24R

Manufacturer Part Number
ASDX015G24R
Description
SENSOR AMP 15PSI GAUG .5-4.5 OUT
Manufacturer
Honeywell Sensing and Control
Series
ASDXr

Specifications of ASDX015G24R

Pressure Type
Gauge
Operating Pressure
15 PSI
Port Size
Male, 0.09" (2.28mm) Tube, Dual
Output
0 ~ 4V
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Top Port
Sensor Output
Voltage
Supply Current
6mA
External Depth
13.97mm
Voltage Rating
5.25V
Port Style
Straight
Pressure Measurement Type
Gage
Operating Pressure Range
0-15 Psi
Sensing Accuracy
2%
No. Of Ports
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
287-1925
287-1925
480-1925
ASDX Series
Pressure Sensors
0 psi to 1 psi through
0 psi to 100 psi
DESCRIPTION
The ASDX Series is an amplified version of Honeywell’s
proven performer and industry leading SDX Series sensor. The
ASDX sensor’s footprint is slightly larger than the SDX;
however, it offers a high level output (4.0 Vdc span) on a very
cost-effective basis. This series is fully calibrated and
temperature compensated with on-board Application Specific
Integrated Circuitry (ASIC).
These DIP (Dual In-line Package) sensors are designed for
use with non-corrosive, non-ionic working fluids; such as air
and dry gases.
FEATURES
ASIC-enhanced output
Wide compensated temperature range 0 °C to 85 °C
[32 °F to 185 °F]
Available in absolute, differential and gage types
Pressure ranges from 0 psi to 1 psi through 0 psi to 100 psi
Accuracy ±2.0% max. V full scale
Quantization step of 3 mV
Response time of 8 ms
Sensors are available to measure absolute, differential and
gage pressures. The absolute sensors have an internal
vacuum reference and an output voltage proportional to
absolute pressure. The differential sensors allow application of
pressure to either side of the sensing diaphragm and may used
for differential or gage measurements. Bidirectional versions
are also available.
All ASDX Series sensors are accurate to within ±2.0% full
scale and are designed for operation from a single 5.0 Vdc
supply.
POTENTIAL APPLICATIONS
Flow calibrators
Ventilation and air flow monitors
Gas flow instrumentation
Dialysis equipment
Sleep apnea monitoring and therapy equipment
Barometry
HVAC controls
Pneumatic controls

Related parts for ASDX015G24R

ASDX015G24R Summary of contents

Page 1

... ASIC-enhanced output • Wide compensated temperature range 0 ° °C [32 °F to 185 °F] • Available in absolute, differential and gage types • Pressure ranges from 0 psi to 1 psi through 0 psi to 100 psi • Accuracy ±2.0% max. V full scale • Quantization step • Response time Sensors are available to measure absolute, differential and gage pressures ...

Page 2

... Reference conditions (unless otherwise noted): Supply voltage Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure. Span is ratiometric to the supply voltage. 3. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line ...

Page 3

... Pins and 8 are internal connections and should not be connected to external circuitry or ground. FIGURE 3. PERFORMANCE CHARACTERISTICS (Error Band Multiplier Over -20 °C to 105 °C [-4 °F to 221 °F]) FIGURE 4. DIMENSIONAL DRAWINGS (For reference only: mm [in].) A2 Package G2 Package ASDXxxxD4 D4 Package Honeywell Sensing and Control ASDXxxxG2 3 ...

Page 4

... However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, Minnesota 55422 www.honeywell.com/sensing (1) Gage Catalog Listing ASDX001G24R ASDX005G24R ASDX015G24R ASDX030G24R ASDX100G24R – – – – – – – – – ...