SSCSANN001PGAA5 Honeywell Sensing and Control, SSCSANN001PGAA5 Datasheet
![SENSOR PRESSURE GAUGE 1PSI SIP](/photos/14/38/143867/ssc_series_sml.jpg)
SSCSANN001PGAA5
Specifications of SSCSANN001PGAA5
Available stocks
Related parts for SSCSANN001PGAA5
SSCSANN001PGAA5 Summary of contents
Page 1
... C and SPI digital output, and in SMT and DIP packages • Absolute, differential, gage and compound types • Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) • Custom calibration available • Various pressure port options * Full Scale Span Best Fit Straight Line ...
Page 2
... SSC Series Standard Accuracy Plastic Silicon Pressure Sensors POTENTIAL APPLICATIONS • Medical: Airflow monitors - Anesthesia machines - - Blood analysis machines Gas chromatography - Gas flow instrumentation - - Kidney dialysis machines Oxygen concentrators - Pneumatic controls - - Respiratory machines Sleep apnea equipment - Ventilators - Table 1. Absolute Maximum Ratings ...
Page 3
... Life may vary depending on specific application in which sensor is utilized. 10. Contact Honeywell Customer Service for detailed material information. Port 2 (Reference Port) high temperature polyamide alumina ceramic epoxy, RTV silicon, glass, gold, solder ) and minimum max Honeywell Sensing and Control 3 ...
Page 4
... SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Figure 1. Nomenclature and Order Guide Notes: 11. The transfer function limits define the output of the sensor at a given pressure input. By specifying P P and P the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer ...
Page 5
... Total Error Band, SIP, Analog Output, 1 psi to 150 psi Figure 2. Transfer Functions and Limits Figure 3. Completed Catalog Listing Example SSCSANN100PGAA3: SIP, AN ports, no diagnostics, 100 psi gage sensor calibration at 3.3 V. SSCSANN100PGAA3 Output vs. Pressure 100 FSS Total 70 Error Band Pressure (psig 100 Honeywell Sensing and Control 5 ...
Page 6
... Unless otherwise specified this applies to all available pressure ports at any temperature with the operating temperature range. 16. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. 17. ...
Page 7
... Analog Figure 4. Package Dimensional Drawings (For reference only: mm [in]) (Other package combinations are possible, please contact Honeywell Customer Service.) Pin 1 Pin 2 ground output NN Pressure Port: Flat Covers, No Pressure Port AN Pressure Port: Axial, Single Port Pin 3 Pin supply Honeywell Sensing and Control 7 ...
Page 8
... SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Figure 4. Package Dimensional Drawings (continued) 8 www.honeywell.com/sensing AA Pressure Port: Axial, Dual Ports RN Pressure Port: Radial, Single Port ...
Page 9
... Total Error Band, SIP, Analog Output, 1 psi to 150 psi Figure 4. Package Dimensional Drawings (continued) DR Pressure Port: Radial, Dual Ports on Opposite Sides RR Pressure Port: Radial, Dual Ports on Same Side Honeywell Sensing and Control 9 ...
Page 10
... SSC Series Standard Accuracy Plastic Silicon Pressure Sensors Figure 4. Package Dimensional Drawings (continued) Figure 4. Package Dimensional Drawings (continued) 10 www.honeywell.com/sensing NB Pressure Port: Axial Ports on Same Side MN Pressure Port: No Ports, O-Ring Mount Port 1 Port 2 ...
Page 11
... Total Error Band, SIP, Analog Output, 1 psi to 150 psi SN Pressure Port: No Ports, Manifold Mount Honeywell Sensing and Control 11 ...
Page 12
WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or ...