ASDXAVX005PG2A5 Honeywell Sensing and Control, ASDXAVX005PG2A5 Datasheet - Page 3

SENSOR PRESS GAGE DIGITAL 0-5PSI

ASDXAVX005PG2A5

Manufacturer Part Number
ASDXAVX005PG2A5
Description
SENSOR PRESS GAGE DIGITAL 0-5PSI
Manufacturer
Honeywell Sensing and Control
Series
ASDXr

Specifications of ASDXAVX005PG2A5

Pressure Type
Gauge
Operating Pressure
5 PSI
Port Size
Male, 0.09" (2.28mm) Tube
Output
ANALOG
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Top Port
Operating Pressure Range
0-5 Psi
Sensor Output
Digital
Supply Current
3.5mA
Voltage Rating
5V
Port Style
Axial
Pressure Measurement Type
Gage
Sensing Accuracy
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-3286
Figure 1. Nomenclature and Order Guide
Notes:
13. Other package combinations are possible, please contact Honeywell Customer Service.
14. The transfer function limits define the output of the sensor at a given pressure input. By specifying the output signal at the maximum (Pmax.)
15. The output type defines which communication protocol the sensor uses to communicate. Available protocols are I
16. Custom pressure ranges are available, please contact Honeywell Customer Service.
17. The pressure units (inches H
18. See Table 5 for an explanation of sensor types.
and minimum (Pmin.) limits of the pressure range, the complete transfer curve for the sensor is defined. See Figure 2 for a graphical
representation of each calibration. For the 12-bit digital output, Table 6 provides the output of the sensor at significant percentages. These
outputs are valid at the rated input voltage of the sensor.
acts only as a slave). This communication protocol is not field selectable, and must be defined when ordering the sensor.
Series
Pressure Port
AV = Axial port on top, vented cover on bottom
RR = Radial port on top, radial port on bottom
AC = Axial port, sealed cover (commonly used
RV = Radial port, single
Future Option
for absolute)
2
0, cm H
2
ASDX
0, psi, mbar, bar, kPa) define the units used during calibration and in the application.
Package Selection
_ _
X
13
_ _ _ _ _
Calibration Selection
Pressure Range
-
010NG = 10 in H
-
025CG = 25 cm H
001PG = 1 psi
005PG = 5 psi
015PG = 15 psi
030PG = 30 psi
100PG = 100 psi
-
025MG = 25 mbar
050MG = 50 mbar
100MG = 100 mbar
200MG = 200 mbar
500MG = 500 mbar
001BG = 1 bar
002BG = 2 bar
007BG = 7 bar
003KG = 3 kPa
004KG = 4 kPa
005KG = 5 kPa
010KG = 10 kPa
020KG = 20 kPa
050KG = 50 kPa
100KG = 100 kPa
200KG = 200 kPa
700KG = 700 kPa
_
Gage
_
_
2
O
2
O
16, 17, 18
005ND = ±5 in H
010ND = ±10 in H
015CD = ±15 cm H
025CD = ±25 cm H
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
-
015MD = ±15 mbar
025MD = ±25 mbar
050MD = ±50 mbar
100MD = ±100 mbar
200MD = ±200 mbar
500MD = ±500 mbar
001BD = ±1 bar
002BD = ±2 bar
-
003KD = ±3 kPa
004KD = ±4 kPa
005KD = ±5 kPa
010KD = ±10 kPa
020KD = ±20 kPa
050KD = ±50 kPa
100KD = ±100 kPa
200KD = ±200 kPa
-
Differential
Transfer Function Limits
A = 10% to 90% calibration
B = 5% to 95% calibration
2
Power Supply Voltage
3 = 3.3 Vdc
5 = 5.0 Vdc
O
2
O
2
2
O
O
Honeywell Sensing and Control
Output Type
S = SPI
2 = I
3 = I
4 = I
5 = I
6 = I
7 = I
-
-
-
-
-
-
015PA = 15 psi
030PA = 30 psi
100PA = 100 psi
-
-
-
-
-
-
001BA = 1 bar
002BA = 2 bar
007BA = 7 bar
-
-
-
-
-
-
100KA = 100 kPa
200KA = 200 kPa
700KA = 700 kPa
2
2
2
2
2
2
Absolute
C, Address 0x28
C, Address 0x38
C, Address 0x48
C, Address 0x58
C, Address 0x68
C, Address 0x78
2
C or half duplex SPI (sensor
15
14
3

Related parts for ASDXAVX005PG2A5