ASDXAVX001PGAA5 Honeywell Sensing and Control, ASDXAVX001PGAA5 Datasheet

SENSOR PRESS GAGE ANALOG 0-1PSI

ASDXAVX001PGAA5

Manufacturer Part Number
ASDXAVX001PGAA5
Description
SENSOR PRESS GAGE ANALOG 0-1PSI
Manufacturer
Honeywell Sensing and Control
Series
ASDXr

Specifications of ASDXAVX001PGAA5

Pressure Type
Gauge
Operating Pressure
1 PSI
Port Size
Male, 0.09" (2.28mm) Tube
Output
ANALOG
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 105°C
Package / Case
8-DIP (0.600", 15.24mm), Top Port
Operating Pressure Range
0-1 Psi
Sensor Output
Analog
Voltage Rating
5V
Port Style
Axial
Pressure Measurement Type
Gage
Sensing Accuracy
2%
Operating Pressure Min
0psi
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-3289
±
DESCRIPTION
The ASDX Series is a Silicon Pressure Sensor offering a
ratiometric analog interface for reading pressure over the
specified full scale pressure span and temperature range.
The ASDX is fully calibrated and temperature compensated for
sensor offset, sensitivity, temperature effects and non-linearity
using an on-board Application Specific Integrated Circuit
(ASIC). Calibrated output values for pressure are updated at
approximately 1 kHz.
The standard ASDX is calibrated over the temperature range
of 0 °C to 85 °C [32 °F to 185 °F]. The sensor is characterized
for operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
Ratiometric 12-bit analog output
Precision ASIC conditioning and temperature
compensated over 0 °C to 85 °C [32 °F to 185 °F]
temperature range
Low operating voltage
Absolute, differential and gage types
Pressure ranges from 10 inches H
Standard calibrations in inches H
bar, kPa
Total error band of ±2.0% of full scale span maximum
RoHS compliant
2
0, cm H
2
0 to 100 psi
2
0, psi, mbar,
These sensors are available to measure absolute, differential
and gage pressures. The absolute versions have an internal
vacuum reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The ASDX Series sensors are intended for use with non-
corrosive, non-ionic working fluids such as air and dry gases.
They are designed and manufactured according to standards
in ISO 9001.
POTENTIAL APPLICATIONS
Flow calibrators
Ventilation and air flow monitors
Gas flow instrumentation
Sleep apnea monitoring and therapy equipment
Barometry
Pneumatic controls
HVAC

Related parts for ASDXAVX001PGAA5

ASDXAVX001PGAA5 Summary of contents

Page 1

... DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering a ratiometric analog interface for reading pressure over the specified full scale pressure span and temperature range. The ASDX is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects and non-linearity using an on-board Application Specific Integrated Circuit (ASIC) ...

Page 2

... The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 7. Overpressure is the maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. ...

Page 3

... Honeywell Sensing and Control 14 3 ...

Page 4

... Output is proportional to difference between applied pressure and built-in reference to vacuum (zero pressure). Gage Output is proportional to difference between applied pressure and atmospheric (ambient) pressure. Output is proportional to difference between pressure applied to each of the pressure ports (Port 1 – Port 2). Differential Figure 2. Transfer Functions and Limits A Calibration, 10% to 90% Figure 3 ...

Page 5

... Description power supply source provides the analog output power supply ground Honeywell Sensing and Control 5 ...

Page 6

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or ...