1 PSI-D-CGRADE-MV All Sensors Corporation, 1 PSI-D-CGRADE-MV Datasheet
1 PSI-D-CGRADE-MV
Specifications of 1 PSI-D-CGRADE-MV
Related parts for 1 PSI-D-CGRADE-MV
1 PSI-D-CGRADE-MV Summary of contents
Page 1
... This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The C-GRADE is a lowest cost version of the millivolt output pressure sensors. The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage acceptable ...
Page 2
... Pressure Sensor Characteristics Maximum Ratings Supply Supply Voltage VS Common-mode pressure Lead Temperature (soldering 2-4 sec.) Standard Pressure Ranges Part Number Operating Pressure 4 INCH-D-CGRADE- “H2O 0.3 PSI-D-CGRADE- O.3 PSI 1 PSI-D-CGRADE- PSI 5 PSI-D-CGRADE- PSI 15 PSI-D-CGRADE- PSI 30 PSI-D-CGRADE- PSI 100 PSI-D-CGRADE- 100 PSI 15 PSI-A-CGRADE- PSIA ...
Page 3
... Performance Characteristics for 1 PSI-D-CGRADE-MV Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (0°C-70°C), note 2 Linearity, hysteresis error, note 4 Span Shift (0°C-70°C), note 2 Performance Characteristics for 5 PSI-D-CGRADE-MV Parameter, note 1 Operating Range, differential pressure ...
Page 4
... HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT 5: T NOTE HE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds. Equivalent Circuit Input Resittance 5 ...