BARO-DO-MIL All Sensors Corporation, BARO-DO-MIL Datasheet

SENSOR 1100MBAR DO DUAL

BARO-DO-MIL

Manufacturer Part Number
BARO-DO-MIL
Description
SENSOR 1100MBAR DO DUAL
Manufacturer
All Sensors Corporation
Datasheet

Specifications of BARO-DO-MIL

Pressure Type
Absolute
Operating Pressure
8.70 ~ 15.95 PSI, 600 ~ 1100 mbar
Port Size
Male, 0.174" ~ 0.19" (4.4mm ~ 4.8mm) Tube, Dual
Output
5V
Voltage - Supply
7V
Termination Style
PCB
Operating Temperature
-40°C ~ 125°C
Package / Case
6-SIP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
442-1098
BARO-DO-MIL
Digital Output Barometer Sensors
Enhanced Digital Output Sensors: Extended temperature range
Physical Dimensions
General Description
The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital output
that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital serial output
(14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and MICROWIRE/
PLUS
In addition to synchronous communications, the Digital Output pressure sensors incorporates a bi-directional, TTL level,
asynchronous serial interfaces mode (hardware selectable 9,600 or 19,200 baud). This mode includes a command set that
allows the host to interrogate the sensor for model information, pressure range, serial number, pressure units and conversion
factor. The command set also allows the host to select a high resolution output mode, make minor adjustments to offset and
has an addressable feature that alows multiple sensors to be tied to the same interface buss.
This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. All signals are 5V
TTL/CMOS compatible.
(27.4)
(6.4)
0.25
1.08
NOTES:
1) Dimensions in inches (millimeters)
®
compatible as well as fully compatible with the All Sensors GA142 Series sensors.
(12.2)
0.48
Pin Size
0.010 x 0.020
(0.25 x 0.50)
(14.0)
0.55
0.174 to 0.190
(4.4 to 4.8)
(16.0)
0.66
Pressure Applied to Port B
Pin 1 2 3 4 5 6
1
(20.3)
(21.6)
(27.9)
0.80
0.85
1.10
A
B
0.10
Typical
(2.54)
Features
• All Combined Errors Over Temperature Less Than 0.1%, Typical
• Wide -40 to 125°C Compensated Temperature Range
• Electrically Compatible to All Sensors GA142 Series
• Enhanced Dual Serial Interface Mode
Applications
• Medical Instrumentation
• Environmental Controls
• Meteorology
4-8
(5.3)
0.21
(10.5)
0.42
Pin Descriptions
P i n Label
1
2
3
4
5
6
Vcc
Data/SI
Clock/SO
Ready/Mode
Convert/BR
Ground
Description
+5V power supply input
Data output for synchronous
mode. Serial in for asynchro-
nous mode.
Clock output for synchronous
mode. Serial out for asynchro-
nous mode.
Ready output for synchronous
mode. Selects asynchronous
mode when held low during
reset.
Convert input for synchronous
mode. Selects one of two baud
rates for asynchronous mode
(low=9,600, high=19,200).
Ground for power and signals

Related parts for BARO-DO-MIL

BARO-DO-MIL Summary of contents

Page 1

... Digital Output Barometer Sensors Enhanced Digital Output Sensors: Extended temperature range General Description The Digital Output pressure sensors are based upon a proprietary surface mapping technology to produce a fully digital output that virtually eliminates all repeatable errors over temperature and pressure. This series provides a 12 bit digital serial output (14 bit in High Resolution Mode) with superior offset, span and linearity characteristics. The output is SPI and MICROWIRE/ ® ...

Page 2

... Absolute Maximum Ratings Supply Voltage (Vcc) Voltage on Any Pin with Respect to Gnd Lead Temperature (soldering 2-4 sec.) Standard Pressure Ranges Part Number Operating Pressure BARO-DO-MIL 600 to 1100 BARO-INHG-DO-MIL BARO-DO-MIL-PCB 600 to 1100 BARO-INHG-DO-MIL-PCB General Performance Characteristics (1) Parameter Resolution Conversion Speed Supply Current Overall Accuracy ...

Page 3

Option: PCB mounted compatible to GA-series and SMRT series Optional 90 degree lead bend 4-10 ...

Page 4

Synchronous Timing Diagram (Note: Asynchronous mode timing is per RS-232. To use RS-232 requires the Maxim MA232 interface circuit for proper voltage level compatibility.) READY [Output CONVERT [Input] t3 CLOCK [Output] t6 DATA [Output] Bit 15 MSB Ref ...

Page 5

... Part Model as given in the data sheet (also order number.) The general model syntax is [Full Scale Pressure]<sp>[Pressure Units]-[Pressure Model]-DO Example: 100 PSI-D-DO Where: Full Scale Pressure=100 Pressure Units=PSI (inH2O, mbar or mmHg available) DO represents Digital Output Notes: 1.) Exception to this syntax is the Barometer. 2.) Custom models may be different. 4-12 ...

Page 6

... Bit 0 : This should not appear if the part has been calibrated Bits 1 thru 7 : indicate computational error when compensated Bit 8: indicates that the pressure applied to the part exceeds the range of the part and is limit to either the high or low limit No response from the part. In the event of a serial number mismatch the part will not respond (to avoid buss contention ...