MGA-30-A-9V-R SSI Technologies Inc, MGA-30-A-9V-R Datasheet - Page 3

SENSOR DIGITAL GAUGE 30PSI LCD

MGA-30-A-9V-R

Manufacturer Part Number
MGA-30-A-9V-R
Description
SENSOR DIGITAL GAUGE 30PSI LCD
Manufacturer
SSI Technologies Inc
Series
MG-9Vr
Datasheet

Specifications of MGA-30-A-9V-R

Pressure Type
Gauge
Operating Pressure
30 PSI
Port Size
Male, 1/4" (6.35mm) NPT
Output
LCD Display
Accuracy
±0.5%
Voltage - Supply
9V
Operating Temperature
-10°C ~ 60°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
734-1159
MGA-30-A-9V-000-000
To see the maximum peak pressure the unit has measured:
Press and hold down the LIGHT/P-H button for 3 seconds.
The maximum pressure reading will be blinking.
maximum pressure read was over the unit’s maximum
pressure range, o.L will be blinking on the display.
To return to the current pressure reading:
LIGHT/P-H button and hold down for 3 seconds.
The
whatever pressure is currently being applied to the port and
to clear the stored maximum peak pressure reading.
To reference your MediaGauge™ digital pressure gage to the
input port: Press and hold the RESET/CLEAR button for 3
seconds.
reference to your input port. For example, if you have 20
psi on the display and then you press and hold the
RESET/CLEAR button for 3 seconds the display will show
0.0 psi. A measurement of 30 psi would then read as 10 psi
on the display.
To reset the MediaGauge™ digital pressure gage: Make sure
the input port is either disconnected or connected to a 0 psi
input. Press and hold down the RESET/CLEAR button for 3
seconds.
To clear the maximum peak pressure reading: Press and hold
down the LIGHT/P-H button for 3 seconds until the
maximum pressure reading appears on the LCD (it will be
blinking). Release the LIGHT/P-H button. Press and hold
down RESET/CLEAR button for 3 seconds.
SSI TECHNOLOGIES, INC.
Controls Division
2643 West Court Street
Janesville, WI 53548-5011
Phone: (608)758-1500
Fax: (608)758-2491
RESET/CLEAR button
The MediaGauge™ MGA-9V will now be
MediaGauge™ (Model MGA-9V) Digital Pressure Gage
SSI Technologies – Application Note PS-AN5
is used to reset the gage to
Product Overview
Press the
If the
3
Installation/Mounting
Electrical Specifications
Supply Voltage
Response Time
Accuracy
LCD Resolution (30 PSI)
LCD Resolution (100; 300 PSI)
Proof Pressure
Burst Pressure
Operating Temperature Range
Storage Temperature Range
1) Mount the MediaGauge™ MGA-9V digital pressure
2) Do no over tighten. Torque to 150 in lbs +/- 1 in lb.
gage on a suitable (1/4” NPT) female fitting. Use
Teflon tape or pipe dope to seal the threads.
Copyright November 6, 2008
SSI Technologies Inc.
All Rights Reserved
9V Battery
< 1 ms
±1.0 FS
0.01
0.1
3 X Full Scale
10 X Full Scale or 15,000
psi whichever is less
-10° to 60°C (14° to 140°F)
-20° to 85°C (-4°to 185°F)
Revision 3