MG-75-A-MD-R SSI Technologies Inc, MG-75-A-MD-R Datasheet - Page 4
MG-75-A-MD-R
Manufacturer Part Number
MG-75-A-MD-R
Description
SENSOR DIGITAL GAUGE 75PSI LCD
Manufacturer
SSI Technologies Inc
Series
MG-MDr
Datasheet
1.MG-300-A-MD-R.pdf
(11 pages)
Specifications of MG-75-A-MD-R
Pressure Type
Gauge
Operating Pressure
75 PSI
Port Size
Male, 1/4" (6.35mm) NPT
Output
LCD Display
Accuracy
±0.25%
Voltage - Supply
12V
Operating Temperature
-10°C ~ 60°C
Package / Case
Stainless Steel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
734-1137
MediaGauge™ MG-MD Panel
MediaGauge™ MG-MD panel has a LCD display and three
multi-functional buttons:
To power on the unit: There is no ON/OFF button on the
MediaGauge™ MG-MD model.
powered on and off via the external 12V supply voltage
source.
When the external supply voltage is between 8 - 30 Vdc, the
LCD will be backlit and will continuously display the
pressure measurements.
SSI TECHNOLOGIES, INC.
Controls Division
2643 West Court Street
Janesville, WI 53548-5011
Phone: (608)758-1500
Fax: (608)758-2491
www.ssitechnologies.com
MediaGauge™ (Model MG-MD) Digital Pressure Gauge
SSI Technologies – Application Note PS-AN7
;
UNIT/SET;
The MG-MD unit is
Product Overview
4
To display the pressure reading in a different pressure unit:
Press the UNIT/SET button until the arrow in the LCD points
to the pressure units desired.
To check the value of the low pressure setting: Press and
release the
displayed for 30 seconds.
To check the value of the high pressure setting: Press and
release the
displayed for 30 seconds.
To see the maximum peak pressure the unit has measured:
Press and hold down the button for 3 seconds.
maximum peak pressure value will be displayed and will
blink on the screen.
To reset the maximum peak pressure: Press and hold down
the button for 3 seconds, and the peak hold value will
reset.
To return to the current pressure reading: Press and hold the
button for 3 seconds and the gauge will be back to the
measurement mode, the current pressure measurement will
be displayed and will not blink.
To reference your MediaGauge™ digital pressure gauge to the
input port: Press and hold down the button and the
button at the same time for 3 seconds. For example, if
you have 20 psi on the display and then you press and hold
down the button and the button simultaneously for 3
seconds, the display will show 0.0 psi. A measurement of
30 psi would then read as 10 psi on the display.
To reset the MediaGauge™ digital pressure gauge: Make sure
the input port is either disconnected or connected to a 0 psi
input.
button at the same time for 3 seconds.
Press and hold down the button and the
button, the high pressure set point will be
button, the low pressure set point will be
Copyright January 30, 2009
SSI Technologies Inc.
All Rights Reserved
Revision 4
RoHS
The