20 INCH-G-4V-REF All Sensors Corporation, 20 INCH-G-4V-REF Datasheet

SENSOR 20" H2O G 4V-REF DUAL

20 INCH-G-4V-REF

Manufacturer Part Number
20 INCH-G-4V-REF
Description
SENSOR 20" H2O G 4V-REF DUAL
Manufacturer
All Sensors Corporation
Datasheet

Specifications of 20 INCH-G-4V-REF

Rohs Status
RoHS non-compliant
Pressure Type
Gauge
Operating Pressure
0.07 PSI, 20" H20
Port Size
Male, 0.19" ~ 0.17" (4.4mm ~ 4.8mm) Tube, Dual
Output
0 ~ 0.25V
Voltage - Supply
5.5 V ~ 16 V
Termination Style
PCB
Operating Temperature
-25°C ~ 85°C
Package / Case
4-SIP
Other names
442-1008
amplified with voltage reference low pressure
1 mbar (0.4 In H2O) to 30 In H2O Pressure Sensors
Physical Dimensions
General Description
The Amplified with Voltage reference line of low pressure sensors is based upon a proprietary technology to
reduce all output offset or common mode errors. This model provides a very stable 4-volt output with superior
output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to
long time period, and position sensitivity are all significantly reduced when compared to conventional compensa-
tion methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to
provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide
temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry
gases and the like.
The output of the device is 0.25 to 4.25 volts. The device operates from any dc. supply voltage of 5.5 to 16 volts.
all sensors
(27.4)
0.25
(6.4)
1.08
(12.2)
0.48
0.010 x 0.020
(0.25 x 0.050)
(14.0)
0.55
4 places for
electrical connection
0.190 to 0.174
(4.8) to (4.4)
Dimensions in inches (mm)
(10.5)
0.414
082302
Features
• 0 to 1 mbar to 0 to 30 In H2O Pressure Ranges
• Fixed Output Voltage of 0.25 to 4.25 volts
• Supply Voltage range of 5.5 to 28 volts
• Temperature Compensated
• Calibrated Zero and Span
Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
PINOUT:
1) +Vsupply
2) Common
3) +Voutput
4) do not
connect to
this pin
Mounting
0.14 (3.6),
typical
Pin 1 2 3 4
1
(20.3)
0.80
(21.6)
(27.9)
0.85
1.10
A
B
(2.54)
0.10
typical
(11.4)
0.45
0.21
(5.3)
01
01
01
01
01

Related parts for 20 INCH-G-4V-REF

20 INCH-G-4V-REF Summary of contents

Page 1

... In H2O H2O Pressure Sensors General Description The Amplified with Voltage reference line of low pressure sensors is based upon a proprietary technology to reduce all output offset or common mode errors. This model provides a very stable 4-volt output with superior output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when compared to conventional compensa- tion methods ...

Page 2

... Standard Pressure Ranges Part Number Operating Pressure 1 MBAR-D-4V-REF 1 INCH-D-4V-REF 1 INCH-G-4V-REF 5 INCH-D-4V-REF 5 INCH-G-4V-REF 10 INCH-D-4V-REF 10 INCH-G-4V-REF H2O 20 INCH-D-4V-REF 20 INCH-G-4V-REF H2O 30 INCH-D-4V-REF 30 INCH-G-4V-REF H2O Performance Characteristics for: 1 MBAR-D-4V-REF Parameter, 1 NOTE Operating Range, differential pressure Output Span, 5 NOTE Offset Voltage @ zero differential pressure Offset Temperature Shift (5° ...

Page 3

... Span Shift (5°C-50°C), note 2 Performance Characteristics for 5 INCH-D-4V-REF Parameter, note 1 Operating Range, differential pressure Output Span, note 5 Offset Voltage @ zero differential pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5° ...

Page 4

... NOTE Minimum 3.90 0.15 2 NOTE Minimum ±1.90 2.15 2 NOTE Minimum 3.90 0.15 2 NOTE amplified with voltage reference low pressure sensors Nominal Maximum Units 5.0 “H2O 4.0 4.10 volt 0.25 0.35 volt ±40 mvolt ±5 mvolt ±5 mvolt ±5 mvolt 0.05 0.25 %fs ± ...

Page 5

... Offset Warm-up Shift, note 3 Offset Position Sensitivity (±1g) Offset Long Term Drift (one year) Linearity, hysteresis error, note 4 Span Shift (5°C-50°C), note 2 Performance Characteristics for 20 INCH-G-4V-REF Parameter, note 1 Operating Range, gage pressure Output Span, note 5 Offset Voltage @ zero pressure Offset Temperature Shift (5°C-50°C), note 2 Offset Warm-up Shift, note 3 Offset Position Sensitivity (± ...

Page 6

... HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT 5: T NOTE HE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE . FOR MINUS TO PLUS FULL SCALE PRESSURE All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others ...

Page 7

San Ignacio, Suite E & F, San Jose, CA 95119 a 408 225 4314 408 225 2079 www.allsensors.com all sensors all sensors all sensors all sensors all sensors ...

Page 8

... amplified with voltage reference low pressure sensors ...