2386 3M, 2386 Datasheet - Page 4

WRIST STRAP DL COND METAL LARGE

2386

Manufacturer Part Number
2386
Description
WRIST STRAP DL COND METAL LARGE
Manufacturer
3M
Series
2380r
Type
Fabricr
Datasheet

Specifications of 2386

Features
Expandable
Strap Type
Wrist Strap (Wristband)
Strap Closure
Expansion
Size
Medium
Color
Black
Number Of Conductors
Dual Wire
Strap Material
Metal
Band Type
Metal Wrist Band
Circumference
6.5 in. (Min.)
Description/function
For use exclusively with 3M workstation monitors
Product
Static Control Products - Various
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Cord Length
-
Cord Plug
-
Cord Type
-
Strap Termination
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
05113871926
98079850172
V. Wall Mounting
The enclosed 3M Dual Lock™ fastening discs
must be screwed to the wall using the attached
template approximately 1,500mm (5 feet) above
the floor. Drill three holes of 5 mm (0.2 in)
diameter at marked locations. Make sure the area
on the 740 in which the Dual Lock™ fastening
strips are placed is free of dust and dirt. Attach the
3M Dual Lock™ fastening strips to the rear of the
740 tester to the bottom and top in parallel; see
drawing for locations.
For securing on the wall, press the 740 firmly
against the discs. For removal of the 740, lift the
top corners with both hands.
4 / 11
Rear of the 740
Template
(1 500 mm)
5 feet
VI. Wrist Strap Test
Put the wrist band on with ground cord attached
and insert the ground cord into the wrist strap
plug-in jack. Depress the metal contact plate and
hold it. One of the indicator LEDs will illuminate.
An illuminated green LED indicates that the wrist
strap performs within the resistance range of 750
kΩ to the upper selected value of 2, 5, 10 or 35
MΩ. If a red "<" LED is illuminated, the current
limiting resistor in the ground cord is bypassed
and the cord has to be replaced. The red ">" LED
indicates that the selected resistance range is
exceeded. Check to see if the high resistance is in
the cord, the wrist band or in the contact between
wrist band and the operator's skin. To check the
resistance of the ground cord, leave the plug end
of the ground cord attached to the tester and
disconnect the snap end from the wrist band.
Connect ground cord snap to the stud in the hand
symbol or press it onto the contact plate and
depress the plate until one of the LEDs is
illuminated.
In some cases, high contact resistance between the
skin and wrist band will cause the tester to show a
red ">" LED condition. This resistance may be
caused by dry skin or the presence of hair in the
wrist area. The use of a skin lotion is
recommended to solve this problem. If a red ">"
LED condition still exists, replace the wrist band.
Note: The use of skin lotions are not
recommended for use with the 3M™ 4600 Series
Thermoplastic Wrist Bands.
If the green LED illuminates
now, the ground cord can be
used.
If the red ">" LED is
illuminated, replace the
ground cord.