10520 Desco, 10520 Datasheet - Page 5

no-image

10520

Manufacturer Part Number
10520
Description
FINISH FLOOR STATGUARD 55GAL
Manufacturer
Desco
Series
Statgaurd®r
Datasheet

Specifications of 10520

Cleaner, Treatment Type
AntiStatic Liquid, Finish
Applications
Floors
Lead Free Status / RoHS Status
Not applicable / Not applicable

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1052000008
Manufacturer:
Molex
Quantity:
11 200
TB-2088 Page 5 of 9
Figure 5. Applying Spray Buff
Equipment needed:
1. Dust mop with an untreated mop or push broom.
2. At 175-300 rpm, use a red pad. At 1000-1500 rpm
3. Spray a small area with a mixture of one part
4. Buff the sprayed area until clean and glossy. All
5. After high speed spray buffing, dry mop the area, if
Physical Properties
Base:
Description:
Abrasion Resistance: Exc. Crockmeter at 50% R.H.
Color:
Density:
Freeze/Thaw Stability: Exc. 3 Cycles at -10°C
pH:
Slip Resistance:
Solids:
Solvent:
Thermal Stability:
Viscosity:
Working Humidity:
Untreated dust mop
Spray bottle
175-1500 rpm buffing machine with appropriate pad
use a white or beige pad.
Statguard
black marks and scuffs should be removed.
needed, with an untreated mop.
®
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: Desco.com
and two parts water. Spray lightly.
Acrylic Polymer
Aqueous Acrylic Emulsion,
Non-hazardous material as
defined in (29 CFR 1915.4)
Off White Opaque
8.42 lbs/gal
8.8
UL Approved*
18%
Water
Exc. 50°C/1 month
3.3 cps
Range 30-60% RH
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
ELECTRICAL PROPERTIES
Meets or exceeds ANSI/ESD S20.20 minimum
recommended technical requirements as an ESD
protective floor or as a primary grounding method
based on Low charging.
Surface Resistance:
Low Charging:
Personal Resistance: <35 megohm @ 50% RH
Charge Decay:
*Underwriters Laboratory (UL) tested for slip resistance only.
Authorization and Registration Number SA6524.
CLEAN ROOM CHARACTERISTICS
** Analysis conducted at Armstrong Corporate
Testing
Figure 6. 19635 Micro Meg Pocket Megohmmeter
To determine reapplication schedule, it is
recommended to test the surface resistance
periodically to ensure that insulative contaminants such
as dirt and grime are not building up on the surface.
The surface should be kept clean. Testing either point
to point resistance (RTT) or resistance to ground
(RTG) will indicate if the floor finish needs surface
maintenance. If the surface is clean, with high
resistance readings this indicates that the floor finish is
Contaminant
Research Center, Lancaster, PA.
Sodium
Fluoride
Chloride
Bromide
Iodide
Dried film testing was completed to simulate
particulating.**
Liquid analysis completed using GLC (gas-liquid
chromatography)**
Dried Film
Zero
Zero
Zero
Zero
Zero
10E7 Ohms @ 50% RH
per ANSI/ESD S7.1
<50 volts
per ANSI/ESD STM97.2
per ANSI/ESD STM97.1
5000v to 0 in 0.01 sec
per FTMS 101C 4046
Liquid (Outgassing)
© 2008 DESCO INDUSTRIES, INC.
Zero
Zero
Zero
Zero
Zero