A16ZJ-3003 Omron, A16ZJ-3003 Datasheet - Page 11

PANEL PLUG RECTANGULAR

A16ZJ-3003

Manufacturer Part Number
A16ZJ-3003
Description
PANEL PLUG RECTANGULAR
Manufacturer
Omron
Type
Pushbuttonr
Datasheets

Specifications of A16ZJ-3003

Accessory Type
Panel Hole Plug
For Use With/related Products
A16 Series
For Use With
Z1392 - SWTCH KNOB RND 2POS SPDT ILL YLWZ1391 - SWTCH KNOB RND 2POS SPDT ILL REDZ1390 - SWTCH KNOB RND 2POS SPDT ILL GRNZ1387 - SWITCH KNOB RND 2-POS SPDTZ1386 - SWITCH KNB RECT 3POS DPDT ILLZ1385 - SWITCH KNB RECT 3POS DPDT ILLZ1384 - SWITCH KNB RECT 3POS DPDT ILLZ1383 - SWITCH KNB RECT 2POS SPDT ILLZ1382 - SWITCH KNB RECT 2POS SPDT ILLZ1381 - SWITCH KNB RECT 2POS SPDT ILLZ1380 - SWITCH KNB RECT 2POS SPDT ILLZ1379 - SWITCH KNB RECT 2POS SPDT ILLZ1378 - SWITCH KNB RECT 2POS SPDT ILLZ1377 - SWITCH KNOB RECT 3-POS DPDTZ1376 - SWITCH KNOB RECT 2-POS SPDTZ1322 - SWITCH PB RECT MOM DPDT YELLOWZ1321 - SWITCH PB RECT MOM DPDT WHITEZ1320 - SWITCH PB RECT MOM DPDT REDZ1319 - SWITCH PB RECT MOM DPDT GREENZ1318 - SWITCH PB RECT MOM DPDT BLACKZ1307 - SWITCH PB RECT MOM DPDT ILLUMZ1306 - SWITCH PB RECT MOM DPDT ILLUMZ1305 - SWITCH PB RECT MOM DPDT ILLUMZ1304 - SWITCH PB RECT MOM DPDT ILLUM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A16ZJ3003
A3BJ-3003
Z1335
Z16ZJ-3003
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches.
Do not apply a voltage between the incandescent
lamp and the terminal that is greater than the rated
voltage. If the incandescent lamp is broken, the
operating part may pop out.
Always turn OFF the power and wait for 10 minutes
before replacing the incandescent lamp. If the lamp is
replaced immediately after the power is turned OFF,
the remaining heat may cause burns.
Mounting
Wiring
Operating Environment
• Always make sure that the power is turned OFF before mounting,
• Do not tighten the mounting nut more than necessary using tools
• Solder terminals and quick-connect terminals (#110) are commonly
• Be sure to use electrical wires that are a size appropriate for the
• Use non-corrosive resin fluid as the flux.
• Make sure that the electric cord is wired so that it does not touch
• After wiring the Switch, maintain an appropriate clearance and
• The IP65 model is designed with a degree of protection so that it
removing, or wiring the Switch, or performing maintenance.
such as pointed-nose pliers. Doing so will damage the mounting
nut.
The tightening torque is 0.29 to 0.49 N·m.
used for terminals.
applied voltage and carry current (conductor size is 0.5 to 0.75
mm
below. If the soldering is not properly performed, the lead wires will
become detached, resulting in short-circuits.
the Unit. If the electric cord touches the Unit, then electric wires with
a heat resistance of 100°C min. must be used.
creepage distance.
will not sustain damage if it is subjected to water from any direction
to the front of the panel.
1. Hand soldering: 350°C, within 3 s
2. Dip soldering: 350°C, within 3 s
Wait for one minute after soldering before exerting any external
force on the solder.
2
). Perform soldering according to the conditions provided
Precautions for Correct Use
WARNING
Using the Microload
• Insert a contact protection circuit, if necessary, to prevent the
• The A16 allows both a standard load (125 V at 5A, 250 V at 3 A)
• The minimum applicable load is the N-level reference value. This
reduction of life expectancy due to extreme wear on the contacts
caused by loads where inrush current occurs when the contact is
opened and closed.
and a microload. If a standard load is applied, however, the
microload area cannot be used. If the microload area is used with a
standard load, the contact surface will become rough, and the
opening and closing of the contact for a microload may become
unreliable.
value indicates the malfunction reference level for the reliability
level of 60% (λ 60) (conforming to JIS C5003).
The equation, λ 60 = 0.5 × 10
estimated malfunction rate is less than 1/2,000,000 operations with
a reliability level of 60%.
30
12
24
5
0
0.1
0.15 mA
Invalid
area
1 mA
1
-4
/operations indicates that the
Microload area
10
100
Current (mA)
1,000
A165K
11