ORD312-1015 MEDER electronic, ORD312-1015 Datasheet
ORD312-1015
Specifications of ORD312-1015
ORD312-1015
Related parts for ORD312-1015
ORD312-1015 Summary of contents
Page 1
... REED SWITCH ORD312 High Power Long Life n GENERAL DESCRIPTION The ORD312 is a small single-contact reed switch designed for general control of medium level loads less than 200 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment ...
Page 2
... ORD312 l ORD312 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current (1) Drop-out Value vs. Pull-in Value Pull-in Value 176 Rated value 10∼30 5min 100max 250min ...
Page 3
... Breakdown voltage DC:V 400 300 200 100 Pull-in Value (5) Electrostatic capacitance pF 0.4 0.3 0.2 0 Pull-in Value (4) Insulation resistance 99 0 (1MHz) ORD312 (DC 100V) Insulation resistance 177 ...
Page 4
... ORD312 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency (1) Operate time (25Hz: 100AT energized) ms 0.5 0.4 0.3 0.2 0 Pull-in Value (3) Release time (25Hz: 100AT energized Drop-out Value 178 Rated value 0.4max 0.3max 0.05max 5900±400 ...
Page 5
... MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2.27kg-10sec) Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % −10 −20 −30 −40 −20 (2) Lead tensile strength 99 0 100 Temperature l ORD312 10kg Breaking load ℃ 120 140 179 ...
Page 6
... ORD312 (2) Temperature cycle (-55℃∼+125 ℃ 100 Before test After test (4) High temperature storage test (+125℃-500H 100 Before test 180 (3) Temperature and humidity cycle 100 80 60 (5) Low temperature storage test 100 80 60 After test - 10℃∼ + 65℃ 80%∼98% ...
Page 7
... Shock test 1) Electrical characteristics (30G: 11ms 100 Before test After test (7) Vibration test (20G: 10∼1000Hz 100 Before test After test 2) Misoperation area (open→close) G 1500 1000 Misoperation area 500 Pull-in Value l ORD312 181 ...
Page 8
... ORD312 n LIFE EXPECTANCY DATA: ORD312 Load conditions Voltage: 5VDC Current: 100mA, 10mA, 20mA Load: Resistive load Load conditions Voltage: 12VDC Current: 5mA, 10mA, 100mA Load: Resistive load Load conditions Voltage: 200VDC Current: 10mA, 50mA, 150mA Load: Resistive load 182 (%) ...