ORD219-1015 MEDER electronic, ORD219-1015 Datasheet
ORD219-1015
Specifications of ORD219-1015
Related parts for ORD219-1015
ORD219-1015 Summary of contents
Page 1
... REED SWITCH ORD219 Miniature High-performance n GENERAL DESCRIPTION The ORD219 is a small single-contact reed switch designed for general control of medium- level loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment ...
Page 2
... ORD219 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current (1) Drop-out Value vs. Pull-in Value Pull-in Value 56 Rated value 10∼30 5min 100max 200min 9 10 min ...
Page 3
... Breakdown voltage DC:V 400 300 200 100 Pull-in Value (5) Electrostatic capacitance pF 0.4 0.3 0.2 0 Pull-in Value (4) Insulation resistance 99 0 (1MHz ORD219 l (DC 100V) Insulation resistance 57 ...
Page 4
... ORD219 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency (1) Operate time (25Hz: 100AT energized) ms 0.5 0.4 0.3 0.2 0 Pull-in Value (3) Release time (25Hz: 100AT energized Drop-out Value 58 Rated value 0.4max 0.3max 0.05max 5900±400 500 (2) Bounce time 99 ...
Page 5
... MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (2.27kg-10sec) Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % −10 −20 −30 −60 −40 −20 (2) Lead tensile strength 99 0 100 Temperature ORD219 10kg Breaking load 120 140 ℃ 59 ...
Page 6
... ORD219 (2) Temperature cycle (-55℃ to 125 ℃ Before test (4) High temperature storage test (+125℃-500H Before test 60 (3) Temperature and humidity cycle After test (5) Low temperature storage test After test -10℃ ℃ 80 Before test After test (-40℃-500H Before test ...
Page 7
... Shock test 1) Electrical characteristics (30G: 11ms Before test After test (7) Vibration test (20G: 10∼1000Hz Before test After test 2) Misoperation area (open→close) G 1500 1000 Misoperation area 500 Pull-in Value ORD219 ...
Page 8
... ORD219 n LIFE EXPECTANCY DATA: ORD219 Load conditions Voltage: 5VDC Current: 100µA , 1mA , 5mA Load: Resistive load Load conditions Voltage: 12VDC Current: 5mA , 10mA , 100mA Load: Resistive load Load conditions Voltage: 24VDC Current: 100mA , 200mA , 400mA Load: Resistive load 62 (%) ...