ORD211-2030 MEDER electronic, ORD211-2030 Datasheet
ORD211-2030
Specifications of ORD211-2030
Related parts for ORD211-2030
ORD211-2030 Summary of contents
Page 1
... ORD211 Ultra-miniature n GENERAL DESCRIPTION The ORD211 is a small single-contact reed switch designed for general control of low-level loads less than 24 V. The contacts are sealed within the glass tube with inert gas to maintain contact reliability. n FEATURES (1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive any influence from the external atmospheric environment ...
Page 2
... ORD211 n ELECTRICAL CHARACTERISTICS Parameter Pull-in Value (PI) Drop-out Value (DO) Contact resistance (CR) Breakdown voltage Insulation resistance Electrostatic capacitance Contact rating Maximum switching voltage Maximum switching current Maximum carry current (1) Drop-out Value vs. Pull-in Value Pull-in Value 40 Rated value 10∼40 5min 100max 150min 9 10 min ...
Page 3
... Breakdown voltage DC:V 400 300 200 100 Pull-in Value (5) Electrostatic capacitance pF 0.4 0.3 0.2 0 Pull-in Value (4) Insulation resistance 99 0 (1MHz ORD211 (DC 100V Insulation resistance 41 ...
Page 4
... ORD211 n OPERATING CHARACTERISTICS Parameter Operate time Bounce time Release time Resonant frequency Maximum operating frequency (1) Operate time (25 Hz: 100AT energized) ms 0.5 0.4 0.3 0.2 0 Pull-in Value (3) Release time (25Hz: 100AT energized) µ Drop-out Value 42 Rated value 0.3max 0.3max 0.05max 7500±500 ...
Page 5
... MECHANICAL CHARACTERISTICS (1) Lead tensile test (static load) (Measurement length: 22mm Before test After test n ENVIRONMENTAL CHARACTERISTICS (1) Temperature characteristics % −10 −20 −30 −40 (2) Lead tensile strength 99 0.1 0 − Temperature l ORD211 10kg Breaking load 100 120 ℃ 43 ...
Page 6
... ORD211 (2) Temperature cycle (-55 ℃ to 125 ℃ Before test After test (4) High temperature storage test (+125℃-500H Before test After test 44 (3) Temperature and humidity cycle -10 ℃ ℃ 80 Before test After test (5) Low temperature storage test (-40℃-500H Before test ...
Page 7
... Shock test 1) Electrical characteristics (30G: 11ms Before test After test (7) Vibration test (20G: 10∼1000Hz Before test After test 2) Misoperation area (open→close) G 1500 1000 Misoperation area 500 Pull-in Value l ORD211 ...
Page 8
... ORD211 n LIFE EXPECTANCY DATA: ORD211 Load conditions Voltage: 5VDC Current: 100 µ Load: Resistive load Load conditions Voltage: 12VDC Current: 5 mA, 10 mA, 100 mA Load: Resistive load Load conditions Voltage: 24VDC Current: 1 mA Load: Resistive load 46 (%) (%) 99.9 99 failure 5mA 30 30 ...