1241.6624.1122000 Schurter Inc, 1241.6624.1122000 Datasheet
1241.6624.1122000
Specifications of 1241.6624.1122000
486-1185
Related parts for 1241.6624.1122000
1241.6624.1122000 Summary of contents
Page 1
... ORDER NUMBERS . ................................................................................................................................. 14 3.1 Order numbers MSM with micro switches of protection class IP40 . ................................................................. 14 3.2 Order numbers MSM with micro switches of protection class IP 67 . ................................................................ 16 3.3 Lettering ........................................................................................................................................................ 17 4 ASSEMBLY . ............................................................................................................................................... 19 ...
Page 2
SCHURTER GmbH D – 79346 Endingen www.schurter.com 6.3 ESD Protection ............................................................................................................................................... 20 6.4 Salt Spray Test . ............................................................................................................................................... 20 7 APPROVALS . ............................................................................................................................................ 21 8 ROHS COMPLIANT ................................................................................................................................ 21 Changes that contribute to technical improvement are subject to alternations Seite Erstelldatum: Ersteller 05.11.2004 ...
Page 3
... The electrical lifetime according to ENEC or UL approbation can vary, depending on the corresponding micro switch, under the lifetime indicated above. The type and license numbers for the individual micro switches can be found in “point 6 approvals”. Changes that contribute to technical improvement are subject to alternations ...
Page 4
... Italically written types on request 1) The electrical lifetime according to ENEC or UL approbation can vary, depending on the corresponding micro switch, under the lifetime indicated above. The type and license numbers for the individual micro switches can be found in “point 6 approvals”. Mechanical Data Actuating Force (single-pole) ...
Page 5
SCHURTER GmbH D – 79346 Endingen www.schurter.com Point Illumination Characteristics red LED Point Illumination Characteristics green LED Point Illumination Characteristics blue LED Point Illumination Recommendation of series resistors for Point Illumination: Material Component Housing Actuator Light Conductor (Point Illumination) Illuminated ...
Page 6
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.2 Component dimensions 2.2.1 Component dimensions MSM 16 MSM 16 ST Legend • Illumination Area • Actuating Area • Width Across Flats • Knurled Nut ...
Page 7
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.2.2 Component dimensions MSM 19 MSM 19 ST MSM 19 PI Legend • Illumination Area • Actuating Area • Width Across Flats • Knurled Nut ...
Page 8
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.2.3 Component dimensions MSM 22 MSM 22 ST MSM 22 PI Legend • Illumination Area • Actuating Area • Width Across Flats • Knurled Nut ...
Page 9
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.2.4 Component dimensions MSM 30 MSM 30 ST MSM 30 PI Legend • Illumination Area • Actuating Area • Width Across Flats • Knurled Nut ...
Page 10
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.3 Actuator Tolerance Range The mounting tolerance range of the actuator varies from 0.2 mm projection length and 0.2 mm short length to the housing edge. The slanting position of the actuator can ...
Page 11
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.4 Hole dimensions MSM 16 ST MSM MSM 19 RI MSM MSM 22 RI MSM MSM 30 RI Changes that contribute to technical improvement ...
Page 12
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.5 Starting Torque MSM 16 MSM 19 MSM 22 MSM request 2.6 Switching Symbols MSM ST / MSM LE Changes that contribute to technical improvement are subject to alternations Seite ...
Page 13
SCHURTER GmbH D – 79346 Endingen www.schurter.com 2.7 Accessories MSM 16 Installation wrench Order number: 0853.0622 MSM 22 Installation wrench Order number: 1141.1337 Changes that contribute to technical improvement are subject to alternations Seite Erstelldatum: Ersteller 05.11.2004 ...
Page 14
... Geändert von: 07.03.2008 Schillak 9674 Ø 22 1241.6631.1110000 1241 ...
Page 15
SCHURTER GmbH D – 79346 Endingen www.schurter.com Mounting Diameter (mm) Electrical Rating max. 0 VDC Standard With Lettering Point Illumination red Point Illumination green Point Illumination blue Ring Illumination red Ring Illumination green Ring Illumination blue Electrical ...
Page 16
... Order numbers MSM with micro switches of protection class IP 67 Mounting Diameter (mm) Electrical Rating max 250VAC Standard Ring Illumination red Combinations with micro switches of the protection class IP 67 are available for following types on request: Standard With Lettering Point Illumination red / green / blue ...
Page 17
SCHURTER GmbH D – 79346 Endingen www.schurter.com 3.3 Lettering The last three digits in the order number define the lettering. 000 No Lettering 001-072 Standard Lettering 101- Customized Lettering Example for ordering with lettering Ordering Indices for Lettering 001 016= ...
Page 18
SCHURTER GmbH D – 79346 Endingen www.schurter.com Lettering Size MSM 16 LE: Single characters: Text, max. 3 characters Text, max. 6 characters: Symbols (indices 037-052): MSM MSM Single characters: Text, max. 3 characters Text, ...
Page 19
... During assembly, the protruding bars of the holder should not be pressed together. 5 PACKAGING MSM Switch MSM 16 MSM 19 MSM 22 MSM 30 1 piece in air cushion bag The nuts with gaskets and corresponding micro switches are packed separately and enclosed in the box. Changes that contribute to technical improvement are subject to alternations Seite Erstelldatum: Ersteller 05.11.2004 Ullmer ...
Page 20
SCHURTER GmbH D – 79346 Endingen www.schurter.com 6 QUALIFICATION TEST 6.1 IP Protection Class IP Protection Class IEC/DIN/EN/ 60529 6.2 IK Protection Class Tested Centrically IK Protection Class DIN EN 50102 Mounting Diameter Protection Class DIN EN ...
Page 21
SCHURTER GmbH D – 79346 Endingen www.schurter.com 7 APPROVALS The listed approvals only refer to the micro switch and not to the complete switch. Micro switch: Type 1050.1151 1050.1102 1050.1103 SS-01 T SS-5 T SS-10 T DC3GL1AA DC1GL1AA DC2GL1AA 8 ...