D3C-1210 Omron, D3C-1210 Datasheet - Page 2

SWITCH SPDT BASIC 130GF NON-SHRT

D3C-1210

Manufacturer Part Number
D3C-1210
Description
SWITCH SPDT BASIC 130GF NON-SHRT
Manufacturer
Omron
Series
D3Cr
Type
Detection Switchr
Datasheets

Specifications of D3C-1210

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
0.1A @ 30VDC
Actuator Type
Angled Toggle (Detector)
Mounting Type
Through Hole
Termination Style
PC Pin
Operating Force
130gf
Contact Form
SPDT
Contact Rating
0.1 Amp
Actuator
Lever, Hinge
Contact Configuration
SPDT
Switch Terminals
Through Hole
Contact Current Max
100mA
Contact Voltage Dc Nom
30V
Supply Voltage
30VDC
Circuitry
SPDT
Microswitch Type
Ultra Subminiature
Body Style
Ultra Subminiature
Current, Rating
0.1 A
Dielectric Strength
250 VAC
Mounting Hole Size
1 mm
Number Of Poles
1
Special Features
Detection Switch, Toggle Actuator with Slide Contacts
Termination
Through Hole
Voltage, Rating
30 VDC
Operating Force Max
1.28N
Contact Current Dc Max
100mA
Rohs Compliant
Yes
Actuator Style
Lever
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
D3C1210
SW224
D3C
Note:
Note:
2
Operating speed
Operating frequency
Insulation resistance
Contact resistance (initial value)
Dielectric strength
Vibration resistance
Shock resistance
Durability (see note 2)
Degree of protection
Degree of protection against electric
shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
Contact
Minimum applicable load (see note) 1 mA at 5 VDC
Characteristics
Contact Specifications
Contact Form
SPDT
1. The data given above are initial values.
2. For testing conditions, consult your OMRON sales representative.
For more information on the minimum applicable load, refer to Using Micro Loads on page 4.
NO COM NC
(3)
(1)
(2)
Specification
Material
Slide
Silver plated
1 mm to 500 mm/s
Mechanical: 200 operations/min max.
Electrical:
100 MΩ min. (at 250 VDC)
50 mΩ max.
250 VAC, 50/60 Hz for 1 min between terminals of same polarity
250 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
50,000 operations min. (30 operations/min)
IEC IP00
Class III
175
–20°C to 80°C (at ambient humidity of 60% max.) (with no icing or condensation)
85% max. (for 5°C to 35°C)
Approx. 0.3 g
30 operations/min max.
2
{approx. 30G} max.
2
{approx. 100G} max.
D3C