D4E-2A10N Omron, D4E-2A10N Datasheet
D4E-2A10N
Specifications of D4E-2A10N
Related parts for D4E-2A10N
D4E-2A10N Summary of contents
Page 1
... Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E • Flat springs with an improved lever ratio of the built-in switch en- sure smooth snap action and long life expectancy. • Protection cover protects the built-in switch from dust and oil. ...
Page 2
... Current XS2F-A421-D90-A AC XS2F-A421-G90-A XS2F-D421-D80A DC XS2F-D421-G80-A Micro load General- purpose without without cable cable D4E-2A@0N D4E-1A20N (see D4E-2A20N note 2) D4E-2B@0N D4E-1B20N (see D4E-2B20N note 2) D4E-2C@0N D4E-1C20N (see D4E-2C20N note 2) D4E-2D@0N D4E-1D20N (see D4E-2D20N note 2) --- D4E-1E20N (see D4E-2E20N note 2) D4E-2F@0N D4E-1F20N (see D4E-2F20N ...
Page 3
... Small Sealed Switch File No. E76675 D4E-@@20N Switches only except for Indicator-equipped Switches LR45746 D4E-@@20N Switches only except for Indicator-equipped Switches R9551015 All models in the table on page 139 (Ask your OMRON representative about other models.) 2003010305086795 Ask your OMRON representative for information on ap- proved models ...
Page 4
... Malfunction Hz, 1.5-mm double amplitude 2 Destruction: 1,000 m/s min. 2 Malfunction: 300 m/s min. Operating: – (with no icing) Operating: 35% to 95% Approx (in case of roller plunger) Micro load Inductive load Non-inductive load Motor load Resistive load ( ( 0.5 A --- --- 0.1 A --- 0.1 A --- 0.1 A --- --- --- --- D4E-@N Small Sealed Switch NO 141 ...
Page 5
... Seal packing withstands a pressure of 186 kPa (D4E's seal packing with- stands a pressure of 98 kPa). Terminal Protection Cover D4E-@N has a wide wiring space horizontally (D4E has a space of 7.5 mm horizontally). Engineering Data Electrical Durability (cos =1) Operating temperature: 5°C to 30°C Operating humidity: 40% to 70%. ...
Page 6
... A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0. 5.8- to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet. Roller Plunger PT D4E-1A00N D4E-1A10N 4.2 D4E-2A00N holes D4E-2A10N OP 21.5 28.4 Roller Plunger D4E-1A20N (See note 4.) PT D4E-2A20N (See note 4.) D4E-1A21N (See note 3.) 4 ...
Page 7
... Plunger PT 3.5 D4E-1C00N +0.2 4.2 dia. 0 D4E-1C10N holes D4E-2C00N D4E-2C10N 4.5 21.5 28.4 Plunger D4E-1C20N (See note 4.) D4E-2C20N (See note 4.) PT +0.2 4.2 D4E-1C21N (See note 3.) 0 holes D4E-2C21N (See note 3 4.5 21.5 28.4 Sealed Roller Plunger D4E-1D00N PT D4E-1D10N D4E-2D00N D4E-2D10N OP 21 ...
Page 8
... Sealed Roller Plunger D4E-1D20N (See note 4.) D4E-2D20N (See note 4.) D4E-1D21N (See note 3.) 3.5 D4E-2D21N (See note 3 21.5 28.4 +0.2 4.2 0 holes Sealed Cross Roller Plunger D4E-1E00N 3.5 D4E-1E10N PT OP 21.5 4.5 28.4 +0.2 4.2 dia. 0 holes Sealed Cross Roller Plunger D4E-1E20N (See note 4.) 3 ...
Page 9
... D4E-2F10N OP 21.5 4.5 28.4 +0.2 4.2 dia. 0 holes Sealed Plunger D4E-1F20N (See note 4.) D4E-2F20N (See note 4.) 3.5 D4E-1F21N (See note 3.) PT D4E-2F21N (See note 3.) OP 21.5 28.4 4.2 holes Roller Lever 3.5 D4E-1G00N D4E-1G10N 4.7 holes D4E-2G00N 19.4 +0.2 4.2 dia. ...
Page 10
... Operating direction +0.2 4.2 dia. 0 holes 15 12 21.5 28.4 One-way Action Roller Lever D4E-1H20N (See note 4.) D4E-2H20N (See note 4.) 3.5 D4E-1H21N (See note 3.) D4E-2H21N (See note 3.) Operating direction +0.2 4.2 dia. 0 holes 15 12 21.5 28.4 Molded Terminal Models Molded Terminal Models The molded-terminal model is available with right-hand, left-hand and underside leads and is recommended for use where the Switch is exposed to dust, oil or moisture ...
Page 11
... AC. Voltage ratings of LED indicators are as shown in the table below. Internal Circuit Type L2 Example: When ordering a D4E DC Model, add the following suffix to the model number. Basic Model: The model number of the D4E-1A23N with a built-in Load Power supply Built-in switch Load ...
Page 12
... The conductor size should be 0.75 mm Refer to the following when wiring. Confirm visually dz dia.: 3.2 D dia Two, 4.3 dia hole 33±0.15 14.5±0.2 dia. 2 and cable diameter should be 7 mm. D dia. d dia. z 1.9 5.2 16.4 5.8 8.0 (mm) D4E-@N Small Sealed Switch 149 ...
Page 13
... Wiring Method D4E-N Round solderless terminal D4E-@N 150 Small Sealed Switch Tightening Torque A loose screw may result in a malfunction. Be sure to tighten each screw to the proper tightening torque as shown below. No. Type 1 Terminal screw (M3) 0.24 to 0.44 N·m 2 Switch mounting screw (M4) 1.18 to 1.37 N·m ...
Page 14
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 15
... Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron247.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ...