D4A-3E01N Omron, D4A-3E01N Datasheet - Page 6

LSW 6A 24VDC LED SPDT PF 1/2

D4A-3E01N

Manufacturer Part Number
D4A-3E01N
Description
LSW 6A 24VDC LED SPDT PF 1/2
Manufacturer
Omron
Series
D4Ar
Datasheet

Specifications of D4A-3E01N

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Side Rotary - No Lever
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Force
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
D4A3E01N
Approved Standard Ratings
UL/CSA
A600
D4A-@1@@N (SPDT, Double-break, Without Indicator)
A300
D4A-@3@@N (SPDT, Double-break, With Neon Lamp)
B600
D4A-@5@@N (DPDT, Double-break, Simultaneous
Operation)
D4A-@7@@N (DPDT, Double-break, Sequential Operation)
D4A-@9@@N (DPDT, Double-break, Center Neutral
Operation)
CCC (GB14048.5)
120 VAC
240 VAC
480 VAC
600 VAC
120 VAC
240 VAC
120 VAC
240 VAC
480 VAC
600 VAC
voltage
voltage
voltage
Rated
Rated
Rated
Applicable category and ratings
AC-15 2 A/125 VAC
current
current
current
Carry
Carry
Carry
10 A
10 A
5 A
Make
Make
Make
30
15
7.5
6.0
60
30
15
12
60
30
Current (A)
Current (A)
Current (A)
Break
Break
Break
3
1.5
0.75
0.6
6
3
1.5
1.2
6
3
Volt-amperes (VA)
Volt-amperes (VA)
Volt-amperes (VA)
Make
7,200
Make
7,200
Make
3,600
Break
Break
Break
720
720
360
Characteristics
Note: The above figures are initial values.
*1. Excluding maintained models.
*2. The values are calculated at an operating temperature of +5°C to +35°C,
*3. 1,500 VAC is applied to the indicator lamp type.
*4. Not including Flexible rods (cat whisker, plastic rod, coil spring, and spring
*1. Excluding low-torque and high-sensitivity models.
*2. Including roller lever low-torque and high-sensitivity operating models.
Degree of protection
(reference standards)
Durability
*2
Operating speed
Operating
frequency
Rated frequency
Insulation resistance
Contact resistance
Temperature rise
Dielectric
strength
Pollution degree
(operating environment)
Protection against electric shock
Vibration
resistance
Shock re-
sistance
Ambient operating humidity
Weight
Item
Ambient tempera-
ture
and an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
wire types).
Mechanical: *1
Electrical:
Mechanical:
Electrical:
Between terminals of
same polarity
Between current-car-
rying metal parts and
ground
Between each termi-
nal and non-current-
carrying metal part
Malfunction: *4
Destruction:
Malfunction: *4
Type Roller lever *1
−40°C to +100°C −20°C to +100°C −10°C to +80°C
IP67 and NEMA 1, 2, 3, 4X, 5, 6P, 12,
and 13
SPDT, double-break, roller lever:
50,000,000 operations min.
DPDT, double-break, roller lever:
30,000,000 operations min.
SPDT, double-break: for 125 VAC,
10 A resistive load: 1,000,000 opera-
tions min.
DPDT, double-break: for 125 VAC, 5 A
resistive load: 750,000 operations min.
1 mm/s to 2 m/s (in case of D4A-3101N
roller lever model)
300 operations/minute
30 operations/minute
50/60 Hz
100 MΩ min. (at 500 VDC) between
terminals of the same polarity, be-
tween current-carrying metal parts and
ground, and between each terminal
and non-current-carrying metal part
25 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min.
2,200 VAC, 50/60 Hz for 1 min. *3
2,200 VAC, 50/60 Hz for 1 min. *3
3
Class I (with grounding terminal)
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
SPDT, double-break, roller lever:
600 m/s
DPDT, double-break, roller lever:
300 m/s
35% to 95%RH (with no icing)
Approx. 290 g (in case of D4A-3101N)
Plunger, flexi-
ble rod *2
2
2
min.
min.
2
min.
D4A-@N
With indicator
6