KST221GLFS C&K Components, KST221GLFS Datasheet
![SWITCH TACT 6.2MM SQ 200GF GWING](/photos/15/36/153649/kst221g_sml.jpg)
KST221GLFS
Specifications of KST221GLFS
Related parts for KST221GLFS
KST221GLFS Summary of contents
Page 1
Product change notification C&K components C&K components SAS - 1 rue Louis de la Verne B.P. 359 F-39105 Dole Cedex - FRANCE Telephone :+33 (0 Facsimile: +33 (0 – www.ck-components.com Document ...
Page 2
Document revision Revision Date A 6-jan-11 C&K components C&K components SAS - 1 rue Louis de la Verne B.P. 359 F-39105 Dole Cedex - FRANCE Telephone :+33 (0 Facsimile: +33 (0 ...
Page 3
Summary 1. Purpose........................................................................................................................................... 4 2. Change definition ............................................................................................................................ 4 3. Change impact and qualification method ....................................................................................... 4 4. Application ...................................................................................................................................... 4 4.1 Overview ................................................................................................................................ 4 4.2 Product range affected........................................................................................................... 4 4.3 Date of application & time frame............................................................................................ 4 4.4 Ordering, ...
Page 4
... C&K components, as design and manufacturing company for micro-miniature tact switches, set up continuous product improvement to go toward zero defects. This continuous improvement action leads to implement a major modification on the KST tact switches series: anti particle central contact will be placed on the lead frame in order to increase product robustness to dust or particle contamination. In addition, new injection tooling & ...
Page 5
Acknowledgement For customer with PPAP procedure, we recommend acknowledging this PCN no later than Feb 4th 2011 at the following email address: ksc.ap@coactive-tech.com. 6. Support For any question, please contact your sales representative or email at Julie.barbier@coactive- tech.com. C&K ...
Page 6
Annex 1: P/N affected by the change Y48A21111FP LFS Kst221g Lfs Y48A21211FP LFS Kst221j Lfs Y48A23111FP LFG Kst223g Lfg Y48A23211FP LFG Kst223j Lfg Y48A41111FP LFS Kst241g Lfs Y48A41211FP LFS Kst241j Lfs Y48A43111FP LFG Kst243g Lfg Y48A43211FP LFG Kst243j Lfg C&K ...
Page 7
Annex 2: Qualification report Please refer to the following pages C&K components C&K components SAS - 1 rue Louis de la Verne B.P. 359 F-39105 Dole Cedex - FRANCE Telephone :+33 (0 Facsimile: +33 (0)3 ...
Page 8
QUALIFICATION REPORT 478-10C Report N° : Family Sub-Family KST Qualification of KST using PCF V2 Assy on machine 6 on April 12 2010 Applicable Documents (Spec, norms…) SPEC N° Title : 2 Specify : 3 § 2 Product ...
Page 9
LABORATORY QUALIFICATION REPORT Product Specification PS-KST-185 Rev B Report N° : page 2/45 478-10C Date : 9-June-2010 Page : 2 28 ...
Page 10
... Without solder paste 1 SOLDERING 1,2 With solder on PCB Visual Examination Mechanical measurements Switching diagram type Switching force (Fa) Force at electrical travel (Fa) Tactile feeling (Δ1) Tactile feeling (Δ1%) Sound feeling (Δ2) Return force (Frr) Electrical travel (Te) MEASUREMENTS 2 Mechanical travel (Tm) AFTER SOLDERING 2 Maximum travel Simultaneity (Tm-Te) ...
Page 11
... Solderability 100 0 0 Solder heat resistance 100 100 0 0 Shear test 100 0 0 Overload on switches 100 100 0 page 4/45 478-10 Report N° : Date : 9-June-2010 Page : 4/28 Lab. report Page FAIT Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 ...
Page 12
QUALIFICATION REPORT TEST GROUP : 0 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 2,20 1,51 0,69 2 2,28 1,37 0,92 3 2,23 1,59 0,63 4 2,39 ...
Page 13
QUALIFICATION REPORT TEST GROUP : 0 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 2,29 1,42 0,86 54 2,30 1,41 0,88 55 2,25 1,38 0,86 56 2,31 ...
Page 14
QUALIFICATION REPORT TEST GROUP : 0 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 105 2,33 1,37 0,96 106 2,17 1,29 0,88 107 2,17 1,34 0,83 108 2,27 1,51 ...
Page 15
Page 8/45 ...
Page 16
Page 9/45 ...
Page 17
Page 10/45 ...
Page 18
QUALIFICATION REPORT TEST GROUP : 0 Electrical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 1 Pass > 1GΩ 26,2 2 Pass > 1GΩ 26,6 3 ...
Page 19
QUALIFICATION REPORT TEST GROUP : 0 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 52 Pass > 1GΩ 26,3 53 Pass > 1GΩ 27,2 54 ...
Page 20
QUALIFICATION REPORT TEST GROUP : 0 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 104 Pass > 1GΩ 26,5 105 Pass > 1GΩ 27,5 106 ...
Page 21
page 14/45 ...
Page 22
page 15/45 ...
Page 23
page 16/45 ...
Page 24
QUALIFICATION REPORT TEST GROUP : 2 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 1,93 1,33 0,60 2 1,96 1,22 0,74 3 1,91 1,38 0,52 4 2,08 ...
Page 25
QUALIFICATION REPORT TEST GROUP : 2 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 1,98 1,26 0,72 55 1,91 1,25 0,66 56 2,00 1,28 0,72 57 1,99 ...
Page 26
QUALIFICATION REPORT TEST GROUP : 2 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 3,90 Cp 1,82 CpK 100 M.OK 100% % M.OK 0 M.N- M.N-OK ...
Page 27
page 20/45 ...
Page 28
page 21/45 ...
Page 29
page 22/45 ...
Page 30
Report N° : LABORATORY Date : 9-juin-10 QUALIFICATION REPORT Page : 8/28 TEST GROUP : 2 TEST NAME : Measurement after soldering Electrical characteristics soldering process MEASUREMENT After Tests /measurements conditions Temperat. 15 à 35 °C Humidity 25 ...
Page 31
QUALIFICATION REPORT TEST GROUP : 3 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Equipments Step of Processus Flow LIFE 1 Number of cycles : 100 000 Sample Fa Fra Fa-Fra N° ...
Page 32
page 25/45 ...
Page 33
QUALIFICATION REPORT TEST GROUP : 3 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Number of cycles : 100 000 Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 1 26,1 Pass > 1GΩ ...
Page 34
page 27/45 ...
Page 35
QUALIFICATION REPORT TEST GROUP : 4 MEASUREMENT Mechanical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 2,04 1,34 22 2,23 1,48 23 2,31 1,53 24 2,16 1,36 25 2,18 1,33 ...
Page 36
QUALIFICATION REPORT TEST GROUP : 4 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Bounces Proof N° mΩ at 250V 21 29,7 Pass > 1GΩ 22 29,8 Pass > 1GΩ 23 ...
Page 37
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of thermal shocks Min. temperature -40°C Max. temperature +85°C Number of cycles 20 Sample Fa Fra Fa-Fra Fa-Fra/Fa N° N ...
Page 38
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of thermal shocks Min. temperature -40°C Max. temperature +85°C Number of cycles 20 Voltage Sample Rc Ri (100V) Bounces Proof ...
Page 39
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of continuous humidity storage Storage temperature 40°C % relative humidity 93% Recovery after storage 1h Sample Fa Fra Fa-Fra N° ...
Page 40
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of continuous humidity storage Storage temperature 40°C % relative humidity 93% Recovery after storage 1h Voltage Sample Rc Ri (100V) ...
Page 41
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Mechanical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of Dry heat storage Storage temperature +85°C Recovery after storage 1H Sample Fa Fra Fa-Fra N° ...
Page 42
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of Dry heat storage Storage temperature +85°C Recovery after storage 1H Voltage Sample Rc Ri (100V) Bounces Proof N° mΩ ...
Page 43
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Mechanical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of Cold storage Storage temperature -55°C Recovery after storage 1H Sample Fa Fra Fa-Fra N° 2,15 ...
Page 44
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of Cold storage Storage temperature -55°C Recovery after storage 1H Voltage Sample Rc Ri (100V) Bounces Proof N° mΩ at ...
Page 45
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of cyclic humidity storage Storage temperature 40 % relative humidity 93% Recovery after storage 1h Sample Fa Fra Fa-Fra N° ...
Page 46
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of cyclic humidity storage Storage temperature % relative humidity Recovery after storage Voltage Sample Rc Ri (100V) Bounces Proof N° ...
Page 47
TEST GROUP : MEASUREMENT Temperat. 15 à 35 °C Picture N° Magnification PICTURE 1 Title : Comment : OK Picture N° Magnification PICTURE 3 Title : Comment : OK Conclusion : Satisfying result ( parts). 8-1 LABORATORY QUALIFICATION ...
Page 48
QUALIFICATION REPORT TEST GROUP : 6 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity • Reflow cycle file : Special file for LF Resistance of solder heat • Number of cycles : 3 Sample Fa Fra ...
Page 49
QUALIFICATION REPORT TEST GROUP : 6 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Bounces Proof N° at 250V mΩ 101 26,1 Pass > 1GΩ 102 27,4 Pass > 1GΩ 103 ...
Page 50
QUALIFICATION REPORT TEST GROUP : 6 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample F Shear N° N 161 63,4 162 66,8 163 77,6 164 80,2 165 82,9 166 80,4 167 85,6 168 85,0 169 ...
Page 51
... M.OK : Percentage of conform Measurements % M.N-OK : Percentage of non conform Measurements 478-10C Report N° : Date : 9-juin-10 Page : 27/28 Overload on switches 86 à 106 kPa Ce Simul F à 1,24 0,08 1,27 1,25 0,07 1,26 1,28 0,03 1,18 1,27 0,02 1,23 1,25 ...
Page 52
... M.N-OK : Number of non conform Measurements 478-10C LABORATORY TEST NAME : 6,8 Robustness After 25 à Pressure ms GΩ 0,00 <5ms ####### 10 10 100 0,0% % M.OK : Percentage of conform Measurements % M.N-OK : Percentage of non conform Measurements 478-10C Report N° : Date : 9-juin-10 Page : 28/28 Overload on switches 86 à 106 kPa ...
Page 53
QUALIFICATION REPORT 477-10 Report N° : Family Sub-Family KST Qualification of KST using PCF V2 Assy on machine April 2010 Applicable Documents (Spec, norms…) SPEC N° Title : 2 Specify : 3 § 2 Product ...
Page 54
LABORATORY QUALIFICATION REPORT Product Specification PS-KST-185 Rev B Report N° : page 2/45 477-10 Date : 9-June-2010 Page : 2 28 ...
Page 55
... Without solder paste 1 SOLDERING 1,2 With solder on PCB Visual Examination Mechanical measurements Switching diagram type Switching force (Fa) Force at electrical travel (Fa) Tactile feeling (Δ1) Tactile feeling (Δ1%) Sound feeling (Δ2) Return force (Frr) Electrical travel (Te) MEASUREMENTS 2 Mechanical travel (Tm) AFTER SOLDERING 2 Maximum travel Simultaneity (Tm-Te) ...
Page 56
... Solderability 100 0 0 Solder heat resistance 100 100 0 0 Shear test 100 0 0 Overload on switches 100 100 0 0 page 4/45 477-10 Report N° : Date : 9-June-2010 Page : 4/28 Lab. report Page FAIT Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 ...
Page 57
QUALIFICATION REPORT TEST GROUP : 0 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 2,86 1,88 0,98 2 3,21 2,00 1,21 3 3,06 2,13 0,93 4 3,26 ...
Page 58
QUALIFICATION REPORT TEST GROUP : 0 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 3,13 2,08 1,04 54 3,15 2,12 1,03 55 3,02 1,96 1,05 56 3,30 ...
Page 59
QUALIFICATION REPORT TEST GROUP : 0 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 105 3,18 2,17 1,02 106 3,25 2,15 1,10 107 3,30 2,32 0,98 108 3,39 2,20 ...
Page 60
Page 8/45 ...
Page 61
Page 9/45 ...
Page 62
Page 10/45 ...
Page 63
QUALIFICATION REPORT TEST GROUP : 0 Electrical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 1 Pass > 1GΩ 27,7 2 Pass > 1GΩ 26,4 3 ...
Page 64
QUALIFICATION REPORT TEST GROUP : 0 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 52 Pass > 1GΩ 26,7 53 Pass > 1GΩ 27,7 54 ...
Page 65
QUALIFICATION REPORT TEST GROUP : 0 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 104 Pass > 1GΩ 29,2 105 Pass > 1GΩ 27,5 106 ...
Page 66
page 14/45 ...
Page 67
page 15/45 ...
Page 68
page 16/45 ...
Page 69
QUALIFICATION REPORT TEST GROUP : 2 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 3,10 1,93 1,17 2 3,15 1,88 1,27 3 3,07 2,04 1,02 4 3,28 ...
Page 70
QUALIFICATION REPORT TEST GROUP : 2 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 3,17 2,09 1,08 55 3,01 1,89 1,12 56 3,25 2,02 1,23 57 3,23 ...
Page 71
QUALIFICATION REPORT TEST GROUP : 2 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 3,30 Cp 2,30 CpK 100 M.OK 100% % M.OK 0 M.N- M.N-OK ...
Page 72
page 20/45 ...
Page 73
page 21/45 ...
Page 74
page 22/45 ...
Page 75
Report N° : LABORATORY Date : 9-juin-10 QUALIFICATION REPORT Page : 8/28 TEST GROUP : 2 TEST NAME : Measurement after soldering MEASUREMENT Electrical characteristics After soldering process Tests /measurements conditions Temperat. 15 à 35 °C Humidity 25 ...
Page 76
QUALIFICATION REPORT TEST GROUP : 3 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Equipments Step of Processus Flow LIFE 1 Number of cycles : 100 000 Sample Fa Fra Fa-Fra N° ...
Page 77
page 25/45 ...
Page 78
QUALIFICATION REPORT TEST GROUP : 3 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Number of cycles : 100 000 Voltage Sample Rc Ri (100V) Proof N° mΩ at 250V GΩ 1 29,6 Pass > 1GΩ ...
Page 79
page 27/45 ...
Page 80
QUALIFICATION REPORT TEST GROUP : 4 MEASUREMENT Mechanical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample Fa Fra Fa-Fra N° 3,07 1,97 1,09 22 3,04 1,82 1,22 23 3,04 1,87 1,17 24 2,99 1,94 ...
Page 81
QUALIFICATION REPORT TEST GROUP : 4 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Bounces Proof N° mΩ at 250V 21 31,2 Pass > 1GΩ 22 30,4 Pass > 1GΩ 23 ...
Page 82
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of thermal shocks Min. temperature -40°C Max. temperature +85°C Number of cycles 20 Sample Fa Fra Fa-Fra Fa-Fra/Fa N° N ...
Page 83
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of thermal shocks Min. temperature -40°C Max. temperature +85°C Number of cycles 20 Voltage Sample Rc Ri (100V) Bounces Proof ...
Page 84
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of continuous humidity storage Storage temperature 40°C % relative humidity 93% Recovery after storage 1h Sample Fa Fra Fa-Fra N° ...
Page 85
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of continuous humidity storage Storage temperature 40°C % relative humidity 0,93 Recovery after storage 1h Voltage Sample Rc Ri (100V) ...
Page 86
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Mechanical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of Dry heat storage Storage temperature +85°C Recovery after storage 1H Sample Fa Fra Fa-Fra N° ...
Page 87
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of Dry heat storage Storage temperature +85°C Recovery after storage 1H Voltage Sample Rc Ri (100V) Bounces Proof N° mΩ ...
Page 88
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Mechanical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of Cold storage Storage temperature -55°C Recovery after storage 1H Sample Fa Fra Fa-Fra N° 3,08 ...
Page 89
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of Cold storage Storage temperature -55°C Recovery after storage 1H Voltage Sample Rc Ri (100V) Bounces Proof N° mΩ at ...
Page 90
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 Mechanical characteristics MEASUREMENT Tests /measurements conditions Temperat. 15 à 35 °C Humidity Characteristics of cyclic humidity storage Storage temperature 40 % relative humidity 93% Recovery after storage 1h Sample Fa Fra Fa-Fra N° ...
Page 91
LABORATORY QUALIFICATION REPORT TEST GROUP : 5 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Characteristics of cyclic humidity storage Storage temperature 40 % relative humidity 93% Recovery after storage 1h Voltage Sample Rc Ri (100V) ...
Page 92
TEST GROUP : MEASUREMENT 15 à 35 °C Temperat. Picture N° Magnification PICTURE 1 Title : Comment : OK Picture N° Magnification PICTURE 3 Title : Comment : OK Conclusion : Satisfying result ( parts). 77-1 LABORATORY QUALIFICATION ...
Page 93
QUALIFICATION REPORT TEST GROUP : 6 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity • Reflow cycle file : Special file for LF Resistance of solder heat • Number of cycles : 3 Sample Fa Fra ...
Page 94
QUALIFICATION REPORT TEST GROUP : 6 MEASUREMENT Electrical characteristics Tests /measurements conditions 15 à 35 °C Temperat. Humidity Voltage Sample Rc Ri (100V) Bounces Proof N° at 250V mΩ 101 27,1 Pass > 1GΩ 102 26,8 Pass > 1GΩ 103 ...
Page 95
QUALIFICATION REPORT TEST GROUP : 6 Mechanical characteristics MEASUREMENT Tests /measurements conditions 15 à 35 °C Temperat. Humidity Sample F Shear N° N 161 66,4 162 63,5 163 66,2 164 79,2 165 78,1 166 75,4 167 72,9 168 86,5 169 ...
Page 96
... M.OK : Percentage of conform Measurements % M.N-OK : Percentage of non conform Measurements 477-10 Report N° : Date : 9-juin-10 Page : 27/28 Overload on switches 86 à 106 kPa Ce Simul F à 1,28 0,05 1,92 1,33 0,00 1,88 1,36 0,00 1,80 1,31 0,07 1,86 1,28 ...
Page 97
... M.N-OK : Number of non conform Measurements 477-10 LABORATORY TEST NAME : 6,8 Robustness After 25 à Pressure ms GΩ 0,00 <5ms ####### 10 10 100 0,0% % M.OK : Percentage of conform Measurements % M.N-OK : Percentage of non conform Measurements 477-10 Report N° : Date : 9-juin-10 Page : 28/28 Overload on switches 86 à 106 kPa ...