C112 21C073 020 10 Amphenol-Tuchel Electronics, C112 21C073 020 10 Datasheet - Page 20

no-image

C112 21C073 020 10

Manufacturer Part Number
C112 21C073 020 10
Description
CABLE SHIELD M-F 3POS PVC 2.0M
Manufacturer
Amphenol-Tuchel Electronics
Series
C112r
Datasheet

Specifications of C112 21C073 020 10

Connector Type
Circular 03 pos Female to Male
Length
6.56' (2.00m)
Cable Type
Round
Color
Multiple
Shielding
Shielded
Usage
Industrial Environments
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
20
General characteristics
Electrical characteristics
Climatic characteristics
Materials
Mechanical characteristics
Other technical characteristics
1
2
3
) In mated position only
) IEC 60664-1 corresponds to DIN VDE 0110
) Contact no. 5 is “first mate – last break“ and can be used for grounding purpose. When grounding the customer must mark the wire.
Number of contacts
Contact resistance
Current carrying capacity
Rated voltage
Rated impulse voltage
Insulation resistance
Pollution degree
Material group
Test voltage
Climatic category
Temperature range
Contact insert
Contact plating
Overmolding
Housing
Knurled screw /
knurled nut
O-Ring
Protection class
Mechanical operation
Insertion force
Withdrawal force
Type of termination
Wire size
Flammability
Locking
Furthermore the user has to ensure that this connector is not mated with such connectors where contact no 5 is under voltage
Standard
IEC 60 512-2, test 2 a
IEC 60 512-3, test 5 b
IEC 60 664-1
IEC 60 664-1
IEC 60 664-1
IEC 60 664-1
IEC 60 512-2, test 3 a
IEC 60 664-1
IEC 60 664-1
IEC 60 644-1
IEC 60 668-1
IEC 60 512-6, test 11 i + j
IEC 60 529
IEC 60 512-5, test 9 a
IEC 60 512-7, test 13 b
IEC 60 512-7, test 13 b
2)
2)
2)
2)
2)
2)
2)
Standard Version
3 / 4 / 5
4 A at T
3+4 cont. 250 V AC / DC
5 cont. 60 V AC / DC
3 + 4cont. 2,5 kV
5 cont. 1,5 kV
> 10
3
I
3 + 4 cont. 1,4 kV AC
5 cont. 1,0 kV AC
25 / 85 / 21
– 25°C - + 85°C
– 13°F - + 185°F
TPU
Au
TPU
CuZn nickel plated
Viton
IP 65 and IP 67 , when properly mated
crimp (overmolded)
0,34 mm
UL 94 HB
Screw coupling
1)
10 m
100 mating cycles
25 N
30 N
8
u
3)
2
(without cable)
= 40°C
(AWG 22)
Shielded
3 / 4 / 5
3 + 4 cont. 60 V AC/DC
5 cont. 60 V AC/DC
3 + 4 cont. 0,8 kV
5 cont. 0,8 kV
0,5 kV AC
3)

Related parts for C112 21C073 020 10