1636897 Phoenix Contact, 1636897 Datasheet - Page 2

HEAVYCON INSERT MODULE FML 1POS

1636897

Manufacturer Part Number
1636897
Description
HEAVYCON INSERT MODULE FML 1POS
Manufacturer
Phoenix Contact
Series
HEAVYCON® Mr
Datasheet

Specifications of 1636897

Connector Type
Module
Gender
Female
Number Of Positions
1
Termination Style
Screw
Voltage Rating
600V
Current Rating
200A
Contact Plating
Silver
Insert / Contact Gender
Female
Number Of Positions / Contacts
1
Product Type
Inserts
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Size
-
Contact Type
-
Lead Free Status / Rohs Status
 Details
Other names
HC-M-HS 200/70-MOD-BU
HC-M-HS 200/70-MOD-BU
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1636897
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Rated surge voltage
Ambient temperature (operation)
Number of positions
Mechanical characteristics
Conductor cross-section
Connection cross-section AWG
Stripping length of the individual wire
Tightening torque
Wire diameter including insulation
Hexagonal socket
Insertion/withdrawal cycles
General characteristics
Number of module slots
Connection method
Inflammability class acc. to UL 94
Pollution degree
Surge voltage category
Assembly instructions
Connection
Order No.: 1636897
8 kV
-40 °C ... 125 °C
1
40 mm² ... 70 mm²
1 ... 2/00
16 mm
9 Nm (40 - 50 mm
10 Nm (70 mm
16 mm
WAF 5
≥ 500
2
Axial screw connection
V0
3
III
- Use only flexible conductors,- Connection of wires with 5 mm an
Allen wrench,- Housing height h ≥ 72 mm,- Connectors may only
be operated without load/voltage.
Note regarding axial connection technology: Only for stranded
wires. The specified conductor cross sections refer to the
geometric cross section of the cable used.Use of cables with a
geometric cross section very different from the cable's nominal
cross section should be checked before use.The wiring space
of the axial screw method is designed for fine strand cables
according to VDE 0295 Class 5. Deviating cable structures (e.g.,
Class 6 cables) should be checked before use.Connection
Before starting to connect, ensure that the tapered screw is
turned back all the way (chamber is open). The cables must not
be twisted. The wires should be inserted as far as they will go in
the contact chamber (until the insulation touches the contact).
Hold wires in position and use socket wrench to tighten. The
used wire end should be cut off before connecting again. The
connection screw may only be retightened once to prevent the
litz wires from breaking. To prevent damage to the contact, the
wire/cable should be mechanically intercepted at an appropriate
distance from the connection point (e.g., by using a plate cutout).
DIN VDE 0100-520:2003-06 contains information on how to do
this correctly. The module cannot be used simultaneously with
the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective
covers.