LA CP7P-JXKX-24-Z OSRAM Opto Semiconductors Inc, LA CP7P-JXKX-24-Z Datasheet - Page 19

LED High Power (> 0.5 Watts) Amber 617nm 60lm 400mA

LA CP7P-JXKX-24-Z

Manufacturer Part Number
LA CP7P-JXKX-24-Z
Description
LED High Power (> 0.5 Watts) Amber 617nm 60lm 400mA
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of LA CP7P-JXKX-24-Z

Illumination Color
Amber
Wavelength/color Temperature
617 nm
Luminous Flux
60 lm
Luminous Intensity
36 cd
Viewing Angle
80 deg
Operating Voltage
2.2 V
Operating Current
400 mA
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+ 110 C
Led Material
AlInGaP
Led Size
2 mm
Lens Appearance
Clear
Lens Shape
Dome
Number Of Leds
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q65110A9067
Released
Revision History:
Previous Version:
Patent List
Patent No.
US 6 066 861
US 6 277 301
US 6 245 259
Wegen der Streichung der LED aus der IEC 60825 erfolgt die Bewertung der Augensicherheit nach dem Standard IEC
62471:2006("photobiological safety of lamps and lamp systems")
Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LED die "exempt"- Gruppe (die sich im
"sichtbaren" Spektralbereich auf eine Expositionsdauer von 10000 s bezieht). Unter realen Umständen (für Expositionsdauer,
Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial
besitzen. Wie nach dem Blick in andere helle Lichtquellen (z.B. Autoscheinwerfer) auch, können temporär eingeschränktes Sehvermögen
und Nachbilder je nach Situation zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen.
Due to the cancellation of the LED from IEC 60825, the evaluation of eye safety occurs according to the standard IEC 62471:2006
("photobiological safety of lamps and lamp systems").
Within the risk grouping system of this CIE standard, the LEDs specified in this data sheet fall into the "exempt" group (relating to devices
in the visible spectrum with an exposure time of 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance),
it is assumed that no endangerment to the eye exists from these devices.
As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their
blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages
can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous
substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement
we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us
unsorted or which we are not obliged to accept, we shall have to invoice you fo r any costs incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
2011-03-21
Page
all
1, 12
10
1, 10
all
19
1
19
1
19
all
1, 17
12
15
7) page 20
Subjects (major changes since last revision)
Preliminary Data Sheet created
JEDEC Level updated
Approx. weight corrected
additional information
color red and yellow added / datasheet reworked
eye safety information added
Typical Luminous Flux, optical efficiency updated
eye safety information updated
Typical Luminous Flux, optical efficiency corrected
eye safety information corrected
Final datasheet created
Taping corrected
Max. Permissible Forward Current updated
Note added
may only be used in life-support devices or systems
2011-03-21
2010-10-28
19
8) page 20
LA CP7P, LR CP7P, LY CP7P
with the express written approval of OSRAM OS.
Date of change
2009-07-20
2009-09-15
2009-09-25
2010-02-26
2010-06-16
2010-08-03
2010-08-19
2010-08-31
2010-09-09
2010-09-09
2010-10-28
2011-03-21
2011-03-21
2011-03-21

Related parts for LA CP7P-JXKX-24-Z