TCS3414CS TAOS, TCS3414CS Datasheet - Page 16

Photodiodes TriColor Sensor RGB, Clear Ch

TCS3414CS

Manufacturer Part Number
TCS3414CS
Description
Photodiodes TriColor Sensor RGB, Clear Ch
Manufacturer
TAOS
Type
Digital Color Light Sensorr
Datasheet

Specifications of TCS3414CS

Peak Wavelength
470 nm
Maximum Rise Time
300 ns
Maximum Fall Time
300 ns
Package / Case
Chipscale-6
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Product
Ambient Light Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TCS3414CS
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
TCS3414CS
Manufacturer:
AMS
Quantity:
600
Part Number:
TCS3414CS
Manufacturer:
AMS
Quantity:
600
TCS3404CS, TCS3414CS
DIGITAL COLOR LIGHT SENSORS
TAOS068 − FEBRUARY 2009
Timing Register (01h)
16
Copyright E 2009, TAOS Inc.
Reset Value:
INTEG_MODE
SYNC_EDGE
PARAM
PARAM
The TIMING register controls the synchronization and integration time of the ADC channels. The Timing
Register settings apply to all four ADC channels. The Timing Register defaults to 00h at power on.
FIELD
Resv
01h
Resv
7
0
BITS
5:4
3:0
3:0
7
6
SYNC_EDGE
Reserved. Write as 0.
Sync pin edge. If SYNC_EDGE is low, the falling edge of the sync pin is used to stop an integration
cycle when INTEG_MODE is 11. If SYNC_EDGE is high, the rising edge of the sync pin is used to
stop an integration cycle when INTEG_MODE is 11.
Selects preset integration time, manual integration (via serial bus), or external synchronization (SYNC
IN) modes.
Uses single, multipurpose bitmapped field to select one of three predefined integration times or set the
number of SYNC IN pulses to count when the INTEG_MODE accumulate mode (11) is selected.
NOTE: INTEG_MODE and TIME/COUNTER fields should be written before ADC_EN is asserted.
6
0
FIELD VALUE
FIELD VALUE
FIELD VALUE
0000
0001
0010
0000
0001
0010
0100
0101
1000
0011
0110
0111
00
01
10
11
INTEG_MODE
0
5
r
Table 5. Timing Register
www.taosinc.com
In this mode, the integrator is free-running and one of the three
internally-generated Nominal Integration Times is selected for each conversion
(see Integration Time table below).
Manually start/stop integration through serial bus using ADC_EN field in Con-
trol Register.
Synchronize exactly one internally-timed integration cycle as specified in the
NOMINAL INTEGRATION TIME beginning 2.4 μs after being initiated by the
SYNC IN pin.
Integrate over specified number of pulses on SYNC IN pin (See SYNC IN
PULSE COUNT table below). Minimum width of sync pulse is 50 μs. SYNC
IN must be low at least 3.6 μs.
NOMINAL INTEGRATION TIME
12 ms
100 ms
400 ms
SYNC IN PULSE COUNT
1
2
4
8
16
32
64
128
256
4
0
0
3
DESCRIPTION
2
0
PARAM
r
MODE
1
0
The LUMENOLOGY r Company
0
0
TIMING

Related parts for TCS3414CS