Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors 350V 20KA 2 Electrode

B88069X2380S102

Manufacturer Part Number
B88069X2380S102
Description
Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors 350V 20KA 2 Electrode
Manufacturer
EPCOS Inc
Series
A8r
Datasheets

Specifications of B88069X2380S102

Peak Pulse Current
20 KA
Dc Breakover Voltage (nominal)
350 V
Number Of Electrodes
2
Dimensions
8 mm D x 60 mm L
Technology
2-Electrode Arrester
Voltage Rating
350 V
Brand/series
A8 Series
Capacitance, Off-state
1.5 pF
Current, Surge
20 kA
Mounting Type
PCB
Primary Type
Surge Suppressor
Protector Type
2 Electrode Arrester
Termination
Lead Wires
Voltage, Protection
350 V ± 20%
Suppressor Type
Gas Discharge
Impulse Sparkover Voltage
700V
Svhc
No SVHC (18-Jun-2010)
Capacitance
1.5pF
Discharge Current Ac Max
20kA
Impulse Discharge Current Max
20kA
Rohs Compliant
Yes
Insulation Resistance
10Gohm
Package / Case
SMD
Sparkover Voltage Dc
350V
Dc Breakover Voltage
350V
Impulse Discharge Current
20kA
Gdt Case Style
Axial Leaded
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B88069X2380S102
Quantity:
1 400
DC spark-over voltage
Impulse spark-over voltage
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles)
Insulation resistance at 100 V
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue
1)
2)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM
Surge Arrester
2-Electrode-Arrester
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
at 100 V/µs
at 1 kV/µs
1) 2)
- for 99 % of measured values
- typical values of distribution
- for 99 % of measured values
- typical values of distribution
dc
(wave 8/20 µs)
Page 1 of 2
Ordering code:
350
< 700
< 650
< 900
< 800
20
25
20
100
> 10
< 1.5
~ 15
~ 0.5
~ 60
~ 1.5
-40 ... +90
40/ 90/ 21
350
YY
O
± 20
- Nominal voltage
- Year of production
- Non radioactive
350 YY O
B88069X2380S102
A81-A350X
V
%
V
V
V
V
kA
kA
A
A
G
pF
V
A
V
g
°C

Related parts for B88069X2380S102

B88069X2380S102 Summary of contents

Page 1

... In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845 Ordering code: 350 < 700 < 650 < 900 < 800 20 (wave 8/20 µ 100 > 10 < 1.5 -40 ... +90 40/ 90/ 21 350 YY O Page A81-A350X B88069X2380S102 V ± Ω °C 350 Nominal voltage - Year of production - Non radioactive ...

Page 2

... Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed Ordering code: Not to scale Dimensions in mm Non controlled document Page A81-A350X B88069X2380S102 ...

Page 3

Surge Arresters Überspannungsableiter Surge arresters in brief Gas-filled surge arresters operate on the gas-physical principle of the highly effective arc discharge. Electrically, surge arresters act as voltage-dependent switches. As soon as the voltage applied to the arrester exceeds the spark-over ...

Page 4

Overview of Type Series Übersicht Typenreihen 2-electrode arresters 2-Elektroden-Ableiter Type series S30 ES EM Light duty Discharge class 1) 2 2 1.5 Dimensions mm (Ø 4.5x3.2x2.7 ...

Page 5

Overview of Type Series Übersicht Typenreihen AC power line protection Schutz von Wechselspannungsnetzen Type series V1 D20 Protection class I & & II Dimensions mm (Ø 12x17 20x4 Page 54/ (V) sdcN U (V) ...

Page 6

Applications Anwendungen Gas-filled surge arresters are classical components for protecting the installations of the telecommunications essential that IT and telecommunications systems - with their high-grade but sensitive electronic circuits - be protected by arresters. They are thus fitted ...

Page 7

Applications Anwendungen Telephone/fax/modem protection Telefon-/Fax-/Modem-Schutz Typical / Typisch: • 230-V arrester/Ableiter • 350-V arrester/Ableiter Two 2-electrode arresters Zwei 2-Elektroden-Ableiter a / Tip b / Ring Arrester Protected device Ableiter Geschütztes Gerät Ground / Erde RAB0200-5 One 3-electrode arrester Ein 3-Elektroden-Ableiter ...

Page 8

Applications Anwendungen CATV/Coax line protection Kabelfernsehen/Coax-Leitungsschutz Typical / Typisch: • 145-V arrester/Ableiter • 150-V arrester/Ableiter • 230-V arrester/Ableiter Shielding / Schirm Arrester Ableiter Ground / Erde Cable TV/coaxial cable protection Arresters are particularly well suited for protecting the coaxial cables ...

Page 9

Mounting Information Montagehinweise Recommended soldering profiles Empfohlene Löttemperaturprofile Wave soldering Wellenlöten 300 10 s ˚C 250 235 ˚C ... 260 ˚C 2nd wave 200 1st wave 5 K/s 2 K/s approx. 200 K/s 150 100 ˚C ... 130 ˚C 100 ...

Related keywords