General Notes:
• All measurements are at an ambient temperature of 25 °C. I PP applies to -40 °C through +85 °C.
• I PP is a repetitive surge rating and is designed to be maintained for the life of the product.
• The devices are bidirectional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• Special voltage (V S and V DRM ) and holding current (I H ) requirements are available upon request.
Bourns
caused by lightning-induced surges, inductive-coupled spikes, and AC power cross conditions. The unique structure and character-
istics of the device are used to create an overvoltage protection device with precise and repeatable turn-on characteristics with low
voltage overshoot and high surge current capabilities.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
I PP (peak pulse current) - maximum rated peak impulse current with
1.2/50 µs waveform
V DRM (peak off-state voltage) - maximum voltage that can be applied
while maintaining off state measured at I DRM
V S (switching voltage) - maximum voltage prior to switching to on-state
measured at 100 V/µs
V T (on-state voltage) - maximum voltage measured at rated on-state
current
Part Number
FVC2300
FVC3100
Voltage Control
Typical Performance Characteristics
Specifi cations
®
voltage control devices are used with high-speed series protectors to protect sensitive circuits from electrical disturbances
Surge Rating
-V
I PP
(A)
4
4
FVC Series Voltage Control Devices
Features
■
■
■
■
■
Formerly
Extremely low capacitance
Very high bandwidth
Small package, minimal PCB area
RoHS compliant*
V DRM
190
275
(V)
I
DRM
I
I
I
T
S
H
+l
-l
260
350
V S
(V)
V
T
brand
I DRM (leakage current) - maximum peak off-state current measured at
V DRM
I S (switching current) - maximum current required to switch to on state
I T (on-state current) - maximum rated continuous on-state current
I H (holding current) - minimum current required to maintain on state
C O (off-state capacitance) - typical off-state capacitance measured at 1
MHz with a 2 V bias
V
V T
(V)
DRM
3
3
Electrical Characteristics
V
S
I DRM
(µA)
5
5
+V
Applications
■
■
■
■
GR-1089
ITU K.20 and K.21
ADSL2+ and VDSL2 linecards
LAN, WAN equipment
(mA)
400
400
I S
(A)
I T
1
1
(mA)
150
150
I H
(pF)
C O
6
6