UTS71412P Souriau Connection Technology, UTS71412P Datasheet - Page 38

CONN RCPT 12X1.6 MALE JAM NUT

UTS71412P

Manufacturer Part Number
UTS71412P
Description
CONN RCPT 12X1.6 MALE JAM NUT
Manufacturer
Souriau Connection Technology
Series
Trim Trio® UTSr
Datasheets

Specifications of UTS71412P

Connector Type
Receptacle for Male Contacts
Number Of Positions
12
Shell Size - Insert
14-12
Contact Type
Crimp
Contact Size
16
Mounting Type
Panel Mount
Fastening Type
Bayonet Lock
Orientation
Keyed
Shell Material, Finish
Thermoplastic
Ingress Protection
IP68/69 - Dust Tight, Waterproof
Note
Contacts Not Provided
Mil Type
MIL-DTL-26482 I
Product Type
Connectors
Contact Style
Pin (Male)
Shell Style
Receptacle
Shell Size
14
Number Of Contacts
12
Insert Arrangement
12
Mounting Style
Wire
Termination Style
Crimp
Current Rating
13 A
Mounting Angle
Straight
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Shell Size, Military
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SOU1295
<<
UTS Series
#1 6 coaxial contacts
Multipiece male contact with coax cable
Multipiece kit details
Note : all dimensions are in mm
AMPHENOL
RG1 78A/U
surprenant
reference
RG1 88/U
RG1 74/U
RG1 61U
RG1 87U
RG1 96U
pn 81 34
21 -598
RG1 79
Contact assembly with dielectric diameter over 1 .4mm - without inner supporting sleeve
Contact assembly with dielectric diameter under 1 .4mm - with inner supporting sleeve
Cable
RMDXK1 0D28
Step 1:
- Assemble outer hyring onto cable
- Assemble supporting sleeve over dielectric and under braid
- Assemble inner socket to inner conductor, push back against
sleeve and crimp
includes
Step 1:
- Assemble outer hyring onto cable
- Assemble inner socket to inner conductor and crimp
RMDXK10D28
Outer contact
Male:
Outer male contact
RMDX60-2
RMDX602D28
RFD26L1D28
RMDXB0553
YOC-074
Outer male contact
RMDX60-2
Supporting
sleeve
compoments
RMDXB0553
Hyring com-
plementary
YOC074 +
YOC074
YOC074
Outer hyring
M10S-1J
Crimp
Inner supporting
tool
Inner contact
Body contact
Outer hyring
Step 2:
- Insert the assembly into the outer male contact
- The cable braid (shield) should now cover the
until the inner socket snaps into place
barrel of the outer male contact as shown
sleeve
Step 2:
- Insert the assembly into the outer male contact
- The cable braid (shield) should now cover the
until the inner socket snaps into place
barrel of the outer male contact as shown
Die set
S22-1
Inner socket
RFD26L-1
Inner socket
RFD26L-1
bushing
74
SL47-1
Stop
Inner supporting
sleeve
RMDXB-055-3
RFD26L1D28
contact
Inner
Outer hyring
YOC-074
Cable stip length
Dielectric
diameter
Step 3:
- Slide outer hyring forward against spring and
crimp in place as shown
Outer hyring
YOC-074
Die set
S23D2
S26D2
S23D2
Step 3:
- Slide outer hyring forward against spring and
4.37
-
-
crimp in place as shown
A
7.95
B
±0.41
±0.41
Locking louver typical
C
bushing
SL46D2
1 5.88
Stop
Grounding louver typical
7.54
9.1 2
Locking louver typical
±0.41
±0.41
±0.41
Grounding louver typical
1 7.53
Strip lengths
of cable
4.37
4.37
4.37
4.37
4.37
7.54
7.54
4.37
4.37
A
±0.41
Cable strip length
Strip lengths
of cable
7.95
7.95
7.95
7.95
7.95
7.95
7.95
9.1 2
9.1 2
B
1 5.88
1 5.88
1 5.88
1 5.88
1 5.88
1 7.53
1 7.53
1 5.88
1 5.88
C
UTS Series
Multipiece female contact with coax cable
Multipiece kit details
Note : all dimensions are in mm
AMPHENOL
RG1 78A/U
surprenant
reference
RG1 88/U
RG1 74/U
RG1 61U
RG1 87U
RG1 96U
pn 81 34
21 -598
RG1 79
Contact assembly with dielectric diameter over 1 .4mm - without inner supporting sleeve
Contact assembly with dielectric diameter under 1 .4mm - with inner supporting sleeve
Cable
RCDXK1D28
includes
Step 1:
- Assemble outer hyring onto cable
- Assemble supporting sleeve over dielectric and under braid
- Assemble inner pin to inner conductor, push back against
sleeve and crimp
Step 1:
- Assemble outer hyring onto cable
- Assemble inner pin to inner conductor and crimp
Outer contact
RCDXK1D28
Female:
Outer hyring
RMD26L1D28
Strip lengths
of cable
RCDX602D28
RCDXB0553
YOC-074
compoments
RMDXB0553
Hyring com-
plementary
Strip lengths
of cable
YOC074 +
YOC074
YOC074
1 1.1 3
Supporting
sleeve
±0.41
6.35
1 1.1 3
M10S-1J
Crimp
Inner supporting
±0.41
tool
±0.41
Inner contact
Body contact
Outer hyring
Step 2:
- Insert the assembly into the outer female contact
- The cable braid (shield) should now cover the
until the inner pin snaps into place
barrel of the outer female contact as shown
sleeve
4.37
Step 2:
- Insert the assembly into the outer female contact
- The cable braid (shield) should now cover the
±0.41
Outer hyring
YOC-074
until the inner pin snaps into place
barrel of the outer female contact as shown
Die set
S22-1
Outer hyring
YOC-074
bushing
75
SL47-1
Stop
Supporting sleeve
RCDXB-055-1
RMD26L1D28
Inner pin
RMD26L-1
contact
Inner
Cable stip length
Dielectric
diameter
Inner pin
RMD26L-1
Step 3:
- Slide outer hyring forward against spring and
crimp in place as shown
Die set
S23D2
S23D2
S23D2
Outer female contact
RCDX60-2
Step 3:
- Slide outer hyring forward against spring and
-
-
A
crimp in place as shown
B
C
bushing
SL46D2
Stop
Outer female contact
RCDX60-2028
4.37
4.37
4.37
4.37
4.37
6.35
6.35
4.37
4.37
A
Cable strip length
B
-
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
1 1.1 3
C
>>

Related parts for UTS71412P