1954283-1 Tyco Electronics, 1954283-1 Datasheet - Page 28

Photovoltaic (Solar) Connectors JUNCTION BOX ASSY Wire Solarlok CONN

1954283-1

Manufacturer Part Number
1954283-1
Description
Photovoltaic (Solar) Connectors JUNCTION BOX ASSY Wire Solarlok CONN
Manufacturer
Tyco Electronics
Datasheet

Specifications of 1954283-1

Product
Junction Box Assemblies
Mounting Style
Wire
Termination Style
Quick Connect
Description/function
Solarlok Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
26
IMPORTANT NOTE
te.com/solar
Catalog 3-1773458-6 | Issue Date 04/2011
Termination of the Cable
Wires and Crimping of
General Comments
of the Connectors
the Contacts
3.1 Handling
Dimensions are in inches and millimeters unless otherwise specified.
Values in brackets are standard equivalents. Dimensions are shown
for reference purposes only. Specifications subject to change.
SOLARLOK Connectivity Systems for PV Installers
Assembly and Installation Guidelines
SOLARLOK plug connectors
ATTENTION : This connector is to be used only to interconnect firmly fixed cables
DO NOT DISCONNECT UNDER LOAD : Current path should only be disconnected
using approved disconnect devices.
SOLARLOK component cable can be labeled with label PN : 1718077-1.
(DO NOT DISCONNECT UNDER LOAD)
PROTECT AGAINST SHOCK : Ensure that conductors and their associated
connectors are separated from opposite polarity components.
Mounting and installation must be done by qualified and trained staff considering
all applying safety regulations. Failure to follow all instructions in Application
Specification 114-18488 (available at www.tycoelectronics.com/documents), including
using only approved TE tooling (if applicable), can result in improper installation
and/or crimping which is dangerous and may cause or contribute to electrical fires.
Should be used only by individuals with proper training and experience.
Any kind of pollution (dust, oil, humidity, etc.) during the assembly process or to the unmated
connector can degrade contact and connector performance. This applies in particular to the
seals and the crimping of the contacts. A clean assembly environment is essential.
When assembling the connectors, the following sequence must be followed:
1 : Stripping the wire to 9 +/- 1mm without damaging the strands
(please refer to application specification #114-74013)
SOLARLOK connectors use different crimp contacts for various wire gauges.
Possible wire gauges are 2.5 mm
The tools to be used are selected based upon the wire gauge.
For the application specification, please refer to specification #114-18488.
2
, 4.0 mm
USA: 1-800-522-6752
Canada: +1-905-475-6222
Mexico: +52 (0) 55-1106-0800
2
, and 6.0 mm
Latin/S. America: +54 (0) 11-4733-2200
Germany: +49 (0) 6251-133-1999
UK: +44 (0) 800-267666
2
, AWG 14, AWG 12 and AWG 10.
France: +33 (0) 1-3420-8686
Netherlands: +31 (0) 73-6246-999
China: +86 (0) 400-820-6015
Fig.1